AQUA SALT EVO - EXTERNAL TIMERS operating mode
This section illustrates the procedure to quickly programme the
EXTERNAL TIMERS
mode of your chlorine generator.
AQUA SALT EVO KEYPAD
1
Switch on or off your AQUA SALT EVO with the ON/OFF key.
2
Press and hold Enter
→
You will switch to the Password Menu.
3
Default password: 0000
→
Press and hold Enter
→
You will switch to the Installer Menu.
4
Press F to scroll the Menu down to Pool Settings.
5
Press Enter to access the submenu.
6
Press F to scroll down to Pool Capacity.
7
Insert the capacity of your pool using UP or Down.
8
Press F to confirm and scroll down to the Generator Operation.
9
Scroll with UP or Down and select External Timers.
10
Press and hold Enter to save the modifications and go back to the Installer Menu.
11
Press F to scroll down to System Settings
→
Press Enter to access the submenu.
12
Press F to scroll down to Cell Type.
13
Select the dimensions of the installed cells using UP or Down.
14
Press and hold Enter to save the modifications and go back to the Installer Menu.
15
Press F to scroll down to Programming
→
Press Enter to access the submenu.
16
Insert the desired percentage of chlorine production using Up and Down.
17
Press and hold Enter to save the modifications and go back to the Installer Menu.
18
Press and hold Enter to go back to the User Menu.
EXAMPLE
: Base Chlorine: 50%
EXPLANATION
: When chlorine generator receives power supply and water flow/
pressure reaches the electrolytic cell, the device produces chlorine for 7.5 minutes (50% of 15 minutes). After
that, chlorine generation stops for 7.5 minutes. This repeats cyclically when generator is set to ON.
When to use
EXTERNAL TIMERS
Use this operating mode of your generator in case you want to
switch it on or off by connecting it to a timer of the pool control
box, or in case you want the generator's activation to depend
on the ignition and shut-down of the recirculation pump of the
system. When this mode is activated, you will only need to
supply the generator and follow the procedure below.