AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO TEMECULA CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
16
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
MULTI LAMP UNITS ELECTRICAL INSTALLATION
4. CONNECT THE TRANSFORMER CAP:
Twist the Transformer Cap onto the Quartz Cap. Do not over
tighten. This is a connection only and is not in contact with water so it does not have to be tight. Do
not use a pipe wrench, pliers or any other tool.
5.
Tighten the Hubl Connector back onto the transformer cap.
Repeat to install each lamp
.
6. FINAL LEAK CHECK:
Do not plug the sterilizer into power yet, turn on pump and check for leaks
again. For illustrations,
SEE PAGE 14.
a. If there are no leaks, continue with electrical installation turn power on to UV.
b. If you have a leak, return to Trouble Shooting Leaks on page 14. Carefully examine this unit
after installation. This unit should not be connected to electricity if there are any leaks.
CAUTION:
Do not use the Aqua Ultraviolet Sterilizer for anything other than its intended use.
CAUTION:
Do not look at or handle UV Lamps when lit outside of the housing. Considerable
Ultraviolet energy is emitted which may produce severe sunburn and/or conjunctivitis. As long as the
UV light is in its housing it is 100% safe for humans and fish.
NOTE:
The average life expectancy of Aqua Ultraviolet Lamps is 14 months of continuous
operation. After 14 months the lamp may still light, but the UV has diminished.
NOTE:
We recommend that the Unit be used in continuous operation for 24 hours a day,
7 days a week. Frequent starts and stops may shorten the life of your Lamps.
WARNING:
If you are using any medication, we recommend shutting down the sterilizer as the
UV Radiation may affect the treatment.
Hubl Connector
Quartz Cap
Transformer Cap