AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO TEMECULA CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
19
AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO, TEMECULA, CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
CLEANING OR REPLACING THE QUARTZ SLEEVE
5. Slide Lamp out, be careful not to slide the Lamp out at an angle, even a slight angle, this may
cause a “U” shaped crack at the end of the Quartz Sleeve, or possible breakage of the Lamp.
Set the lamp on a secure level surface to avoid breakage.
1.
Unplug the Unit from the power source and turn off the pump.
3.
Unscrew the Davis or Hubl Connector located
behind the Transformer Cap, this allows your
Transformer Cap to spin freely.
4.
Twist off the Transformer Cap.
NOTE:
The Lamps and Quartz Sleeves should be handled with care. Lamps and Quartz
Sleeves are not warranted against breakage and damage.
2. Disconnect Venturi Hose from
the Bottom Quartz Cap Barb.
Disconnect the Optional Air Dryer
Hose if installed.
Unscrew Davis Connector
Transformer Cap
Unscrew Transformer Cap
TM
TM
INLET
TO OPTIONAL
AIR DRYER
(NOT SUPPLIED)
RETURN
ELBOW
BARB
UNIONS
TRANSFORMER
VENTURI
(Not Supplied)
6. Take the Unit offline by twisting and
undoing the unions.
Ozone Top
Quartz Cap
Ozone Bottom
Quartz Cap
Union
EZ Twist Top
EZ Twist Top
7. Remove the Top Quartz Cap and
the Bottom Quartz Cap.
(Remove both Blue Caps)