AQUA ULTRAVIOLET 42371 AVENIDA ALVARADO TEMECULA CA 92590 TEL: 951-296-3480 FAX: 951-296-3490
12
1/2” Barb
3/4” Barb
Cut here on line
with hacksaw
to make 3/4”
Barb
For 3/4” threaded units:
b. The barbs have been Teflon taped for
you to prevent leakage. Install barbs,
hose and hose clamps. (Hose and
hose clamps are not included.)
a. Locate the barbs included with your
unit. Barbs are fitted for either 3⁄4” or
1⁄2” hose (see illustration).
For 2” Slip Fitted Units:
80, 114, 120, 160, 200, 240 cut 2 pieces of sch 40
2” PVC pipe to the length of 2-3/8” (supplied by
customer). This pipe is used to attach the UV
sterilizer to the unions that were provided.
Use only PVC glue and primer.
3. Based on your personal plumbing configuration, additional plumbing supplies may be needed.
4. Make sure the unit is mounted securely before operating.
LEAK TEST: Do not install the Lamp or electrical components yet. After all connections have been
made, turn on the pump and run for five minutes to check for leaks.
a. If there are no leaks, turn pump off and continue installing the lamp (on page 15).
For units 8,15, 25, 57 and 114 watt. For 80 watt and 120- 240 watt continue to electrical
installation on page 16.
b. If unit leaks turn pump off and continue to troubleshooting leaks on page 14.
1. You can use mounting brackets (A40124 that can be purchased from us) or plumber’s straps to
attach your unit to a wall or firm surface.
CAUTION: Your Aqua Ultraviolet unit is not submersible. If this unit falls into the water, turn main
power off and then retrieve it. Do not attempt to use this sterilizer if it has been submerged. Do
not operate this unit if it has a damaged cord or plug, if it is malfunctioning or if it has been
dropped or been damaged in any manner.
2. The Unit should be installed after the filter on the return line. This helps ensure that the water is
clear of debris and impurities that could inhibit the disinfection process. The Unit can be installed
before the filter, however, it will take longer to work. Note: You increase the risk of breaking
the Quartz Sleeve and Lamp if debris enters the unit when installed before your filter.
OZONE UV INSTALLATION INSTRUCTIONS
For 2” slip fitted units:
8, 15, 25, 40, 57 Watt Units glue existing pipe
into the unions provided on unit.
Customers
Existing Pipe
2” Union
SCH 40 2” PVC Pipe
Supplied by Customer