Eradicator II AIF Systems
Installation, Operation,and
Maintenance Manual
Re-installing a replacement Control Valve:
1. Place the new control valve over the base connection,
insert the connnection fitting into the base.
see page 16 figure 2
2. Thread the base nut on to the base adapter - do not tighten more than
hand tight.
3. Once the control valve is mounted on the media tank, move the
system to align with the pipe connections.
4. Slide the system onto the pipe connections at the bypass valve.
5. Thread the connnection nuts onto the valve threads -Clockwise
thread direction.
6. Do not over tighten, these connections have an O-Ring seal, Hand
Tight Only.
7. Insert Air Injection fitting into it’s position and install the locking clip.
(see page 16 figure 1)
8. Insert the Drain line into it’s position and install the lock clip.
(see page
16 figure 1)
9. Plug unit into the electrical outlet.
10. Press “Next” and “Regen” buttons to reset control.
11. Set clock to current time of day.
12. Carefully turn water on to the system, open just the inlet valve handle
on the bypass.
see figure 3
13. Examine all connections to ensure that there is a 100% seal with No
Water Leaks.
14. Press “Regen” for 3 seconds to start a regeneration.
15. Let the system finish a complete regeneration.
16. Open the second valve handle (outlet) on the bypass.
see figure 3
Service
Inlet
Handle
Connection
Nut
figure 3
Tighten base and connection nut
fittings
Hand Tight
only.
Caution:
When turning water back on, if there
are any leaks detected, immediately
turn off the water, loosen the leaky
fitting or fittings, check o-rings - clean
and reseat, and re-connect fittings.
Turn on water and make sure there
are no leaks before continuing return
to service.
Note:
Outlet
Handle