background image

© 2014  New Aqua LLC dba Aqua Systems  •  7785 East US Hwy 36 • Avon, IN 46123

3

Eradicator II AIF Systems

Installation, Operation,and

Maintenance Manual

Table of Contents

Owner Information ............................................................................................................................... 2

Introduction .......................................................................................................................................... 2

How the Eradicator Works .................................................................................................................. 4

Pre Install Review ................................................................................................................................ 6

Requirements for Proper Operation: ..................................................................................................................................6

Location Data ....................................................................................................................................... 6

Pre Assembly ....................................................................................................................................... 7

Bypass Operation ................................................................................................................................ 8

Installation ....................................................................................................................................... 9-11

AIF Placement .......................................................................................................................................................................9

Start Up ............................................................................................................................................... 12

Programming ................................................................................................................................ 13-15

Service ................................................................................................................................................ 16

Parts Diagrams..............................................................................................................................18-27

Service Guide..................................................................................................................................... 28

Drive Assembly ...................................................................................................................................................................28

Drive Cap Assembly, Main Piston and Regenerant Piston .............................................................................................29

Spacer Stack Assembly .....................................................................................................................................................30

Injector Cap, Screen, Injector Plug and Injector..............................................................................................................31

Refill Flow Control Assembly or Refill Port Plug

 ............................................................................................................31

Water Meter or Meter Plug .................................................................................................................................................32

Bypass Valve.......................................................................................................................................................................32

Troubleshooting ........................................................................................................................... 34-36

Notes................................................................................................................................................... 37

Summary of Contents for Eradicator II AIF

Page 1: ...6123 1 Eradicator II AIF Systems Installation Operation and Maintenance Manual Eradicator II AIF Air Induction Filter Systems Installation Operation and Maintenance Manual 114 Vista Parkway Avon IN 46...

Page 2: ...fundamentals of the product line and the standard models However it is possible that your AIF system was designed to be site specific Refer to the model number if you have questions for your system p...

Page 3: ...r Proper Operation 6 Location Data 6 Pre Assembly 7 Bypass Operation 8 Installation 9 11 AIF Placement 9 Start Up 12 Programming 13 15 Service 16 Parts Diagrams 18 27 Service Guide 28 Drive Assembly 2...

Page 4: ...olume Air is inducted to system before returning to the treatment cycle Water in passes through air head Treated water exits through distributor Water inlet is reversed in backwash cycle Air water to...

Page 5: ...must include the pH adjustment option when treating iron The water supply must have adequate flow and pressure to backwash the applied system Be sure to reference the required backwash rate of a spec...

Page 6: ...tion with a code compliant air gap It is critical that the drain be secured tightly at each end and anchored throughout the run The AIF systems will jolt the drain line during the release of air Be su...

Page 7: ...nt to the plumbing system The bypass is designed to accommodate minor plumbing misalignments but is not designed to support the weight of a system or the plumbing figure 1 Connection ports on back of...

Page 8: ...le not allowing water to exit from the con trol valve to the plumbing see figure 3 4 Shut Off Position The inlet handle points to the center of the bypass valve and the outlet handle points in the dir...

Page 9: ...ng and o ring Heat from soldering or solvent cements may damage the nut split ring or o ring Solder joints should be cool and solvent cements should be set before installing the nut split ring and o r...

Page 10: ...let and outlet pipes to retain continuity of the plumbing 8 Connect the drain on the AIF system to an approved air gap drain When using the 5 8 poly tubing for the drain line con nect the nut to the l...

Page 11: ...ater Conditioner Drain with code air gap connection Untreated water Bypass Outside spigots Filtered Hard Water Bypass Water Heater 12 of pipe between softener and heater 3 Valve Bypass Optional Well L...

Page 12: ...amount of time You must let the system complete the air induction cycle which will be 30 40 minutes depending on the system size 5 Once the air induction cycle has been completed the Eradicator contr...

Page 13: ...rent Time hour Set the hour of the day using Up or Down buttons AM PM toggles after 12 Press NEXT to go to step 3 3 Current Time minutes Set the minutes of the day using Up or Down buttons Press NEXT...

Page 14: ...Up or Down buttons Press NEXT to set energy saver 5 Energy Saver Use the Up or Down buttons to activate or cancel the energy saver OFF Backlight always on ON Back light off after 5 minutes of inactivi...

Page 15: ...s for it usually referred to as manual regeneration There may be a period of heavy water usage because of guests or a heavy laundry day 4 To initiate a manual regeneration immediately press and hold t...

Page 16: ...se you may pull the system away from the plumbing see note at right 8 With the system off of the plumbing you can loosen the base nut to remove the valve from the media tank see figure 2 Service Make...

Page 17: ...g clip see page 16 figure 1 8 Insert the Drain line into it s position and install the lock clip see page 16 figure 1 9 Plug unit into the electrical outlet 10 Press Next and Regen buttons to reset co...

Page 18: ...F Systems Installation Operation and Maintenance Manual Parts Diagrams Quick Connect Assembly No Part No Description Qty 1 02910182 Tank Adapter items 1 4 1 2 02910183 Tank Nut 1 3 02910184 Split Ring...

Page 19: ...Part No Description Qty 1 02910301 SCII Front Cover Assy 1 2 02910128 Motor 1 3 02910127 Drive Bracket and Spring Clip 1 4 02910300 SCII ALX PC Board 1 or 02910299 SCII AQX PC Board 1 5 02910132 Drive...

Page 20: ...s Installation Operation and Maintenance Manual Parts Diagrams Quick Connect Assembly No Part No Description Qty 1 02910111 Spacer Stack Assy 1 2 02910110 Drive Cap Assy 1 3 02910141 O Ring 228 1 4 02...

Page 21: ...Screen 1 4 02910123 Injector Assy Z Plug 1 02910112 Injector Assy A Black 02910113 Injector Assy B Brown 02910114 Injector Assy C Violet 02910115 Injector Assy D Red 02910116 Injector Assy E White 5...

Page 22: ...ms Installation Operation and Maintenance Manual Parts Diagrams Air Injection Port No Part No Description Qty 2 03310730 Elbow Locking Clip 1 3 03310738 Polytube Insert 3 8 1 4 03310732 Nut 3 8 1 5 03...

Page 23: ...Insert 5 8 1 3 02950121 Nut 3 4 Drain Elbow 1 4 02910152 Drain Elbow 3 4 Male Assy 1 5 02910154 O Ring 019 1 6 02910153 DLFC Retainer Assy 1 02950124 DLFC 0 7 gpm for 3 4 02950125 DLFC 1 0 gpm for 3 4...

Page 24: ...IN 46123 24 Eradicator II AIF Systems Installation Operation and Maintenance Manual Parts Diagrams Meter Assy No Part No Description Qty 1 02910148 Nut 1 QC 1 2 02910108 Meter Assy 1 3 02910140 Turbin...

Page 25: ...cription Qty 1 02910148 Nut 1 Quick Connect 2 2 02910147 Split Ring 2 3 02910126 O Ring 215 2 4 02910146 Fitting 1 PVC Male NPT Elbow 2 Not Shown 22302027 Test Port Valve 1 02950002 Complete PVC Male...

Page 26: ...1 Quick Connect 2 2 02910147 Split Ring 2 3 02910126 O Ring 215 2 4 02910142 Bypass 1 Rotor 2 5 02910143 Bypass Cap 2 6 02910187 Bypass Handle Gray 2 7 02910144 Bypass Rotor Seal Retainer 2 8 0291014...

Page 27: ...LLC dba Aqua Systems 7785 East US Hwy 36 Avon IN 46123 27 Eradicator II AIF Systems Installation Operation and Maintenance Manual Parts Diagrams Valve Wrench No Part No Description Qty Shown 02950123...

Page 28: ...the drive bracket start by removing the plugs for the power source and the water meter Unweave the wires from the side holders Two tabs on the top of the drive back plate hold the drive bracket in pla...

Page 29: ...d hold NEXT and REGEN buttons for 3 seconds or unplug power source jack black wire and plug back in This resets the electronics and establishes the service piston position The display should flash all...

Page 30: ...ack o ring on the spacer stack assembly is no longer visible through the drain port Spacer Stack Assembly To access the spacer stack assembly remove the drive assembly drive cap assembly and piston Th...

Page 31: ...combination of the up flow main piston and the regenerant piston or c for backwash only systems a plug is in the DN hole and in the UP hole and that the piston only has a down flow main piston the re...

Page 32: ...orward on the turbine to remove it from the shaft Do not use a wire brush to clean Wipe with a clean cloth or chemically clean in dilute sodium bisulfite or vinegar The turbine can be immersed in the...

Page 33: ...heir correct orientation To install the gray arrow handles correctly keep the handles pointed in the same direction as the arrows engraved on the control valve body while tightening the bypass valve c...

Page 34: ...d Check control valve set up procedure regen eration time option e Control valve set at NORMAL on 0 e Check control valve set up procedure regen eration time option 5 SYSTEM ERROR Red Screen showing E...

Page 35: ...and held a Transformer unplugged a Connect transformer b No electric power at outlet b Repair outlet or use working outlet c Broken drive gear or drive cap as sembly c Replace drive gear or drive cap...

Page 36: ...r reaches the water heater it may take several days to flush out Water usage during regeneration can result in consistent or intermittent break through of iron and or sulfur Be sure that water using a...

Page 37: ...2014 New Aqua LLC dba Aqua Systems 7785 East US Hwy 36 Avon IN 46123 37 Eradicator II AIF Systems Installation Operation and Maintenance Manual Installation Operation and Maintenance Manual Notes...

Page 38: ...2014 New Aqua LLC dba Aqua Systems 7785 East US Hwy 36 Avon IN 46123 38 Eradicator II AIF Systems Installation Operation and Maintenance Manual...

Page 39: ...2014 New Aqua LLC dba Aqua Systems 7785 East US Hwy 36 Avon IN 46123 39 Eradicator II AIF Systems Installation Operation and Maintenance Manual...

Page 40: ...2014 New Aqua LLC 2 2014 Rev 1...

Reviews: