background image

13. Water In 

16. Water Out 

(Return to Aquarium) 

17. Water out 

(To Marisys) 

17. Water return 

(Back to Aquarium) 

22. Waste Hose 

24. Container 

(Not included) 

18. Protein Skimmer Air Pump 

(Fit a check valve if placed on the floor) 

12. Priming Pump 

20. Check Valve 

21. Air Control Valve 

26. Protein Skimmer Height Adjuster 

8.  Overflow Box 

2. Filter Box 

19. Protein Skimmer Airline Connector 

1. Media Access Lid 

15. Water Bridge 

27. Priming Chamber 

Duck Bill Outlet 

28. Max 

29. Min 

14. V-Joint  

1. MariSys Complete System. (Diagram 1)  

5

Summary of Contents for MariSys 240

Page 1: ...MariSys 240 Complete step by step instruction booklet ...

Page 2: ...plug or receptacle does get wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the receptacle 3 Close supervision is necessary when the appliance is used by or near children 4 Always unplug the filter from the electrical outlet when not in use before putting on or taking off parts before a...

Page 3: ...as been assembled This product is shipped to you in a factory sealed carton Should the product malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection Replacement Parts Filter Media Use Aqua One Genuine Spare Parts Only See your local Aqua One Dealer and look for the number listed below for the spare part you req...

Page 4: ...bon Pad Media Basket 1 Media Basket 3 Wool x 3 Activated Carbon Pillow Media Basket 2 Bio Balls CeramiSub Drip Tray Please Note This filter media set up above is a guide For more information regarding filter media please consult your Aqua One specialist 4 ...

Page 5: ...tein Skimmer Air Pump Fit a check valve if placed on the floor 12 Priming Pump 20 Check Valve 21 Air Control Valve 26 Protein Skimmer Height Adjuster 8 Overflow Box 2 Filter Box 19 Protein Skimmer Airline Connector 1 Media Access Lid 15 Water Bridge 27 Priming Chamber Duck Bill Outlet 28 Max 29 Min 14 V Joint 1 MariSys Complete System Diagram 1 5 ...

Page 6: ...Basket 3 CreamiSub Carbon Pillow Airstone Stop 5 Power Head Outlet Inlet Airstone Housing 25 Reaction Chamber Lid Waste Out 10 Water Level Adjuster 11 Screw Adjuster 9 Adjusting Screws 23 Protein Skimmer Collection Cup 7 Power Cord Cutout 4 8 Overflow Box 3 Overflow Box Diagram 3 2 MariSys Diagram 2 6 Power Head Protein Skimmer Housing 6 ...

Page 7: ...the adjusting screws anti clockwise this will reduce the height of the Overflow Box To raise the water level in the aquarium turn the adjusting screws clockwise to move the box back up Setting up the Filter Media For the following section refer to Diagrams 1 2 on pages 3 5 6 of this instruction booklet Locate and organise all parts before assembly Familiarise yourself with the parts and where they...

Page 8: ...e should be positioned about 1 5 2cm from the bottom of the Reaction Chamber The aquarium s water level can also be raised or lowered by adjusting the Water Level Adjuster 10 Raising the tube will cause the aquarium s water level to rise and lowering the Water Level Adjuster will cause the aquarium s water level to drop 3 Remove the pre filter pad rinse it under water and place back into the Overf...

Page 9: ...n wait 5 minutes If still too few turn the screw another quarter turn It is best to adjust slowly to achieve the desired level of bubbles B If there are too many bubbles and the Collection Cup is overflowing rapidly slowly close the Air Control Valve to achieve desired bubble flow 6 To further adjust and fine tune the Protein Skimmer loosen the Height Adjuster 26 located at the base of the Collect...

Page 10: ...d reconnect it to the system To ensure optimum filter performance routine maintenance should be performed monthly or less depending on size of tank amount of fish and number of daily feeding If the filter and media are neglected the filter media will become clogged and unable to collect waste material This can affect aquarium water quality and possibly the health of the tank inhabitants Grimy wast...

Page 11: ...Cleaning your Power Head Inlet Elbow Impeller Cover Lock Impeller Cover Impeller Blades Impeller Motor Outlet Base Rubber End Cap Ceramic Shaft O ring 11 ...

Page 12: ... Maintenance section in this instruction booklet WATER LEAKING AT FLEXIBLE HOSING CONNECTIONS 1 Disconnect Flexible Hoses from connectors on the MariSys and Overflow Box and clean connectors thoroughly with an Aqua One Double Ended Pipe Brush Reconnect and tighten hose clamps snugly 2 If the Flexible Hosing has slipped from original position remove and clean area then reconnect and tighten hose cl...

Page 13: ...mer Air Pump with new ones 3 Check air line for kinks 4 Check the Air Control Valve and Check Valve OVERFLOW BOX NOT FUNCTIONING 1 Check power supply and confirm Priming Pump is plugged in 2 No water in Overflow Box add water 3 Check Overflow Box for obstacles 4 Check Hosing and Tubing for kinks or obstructions PRIMING PUMP NOT RUNNING 1 Check power supply and confirm Priming Pump is plugged in 2 ...

Page 14: ...ed in Australia by Aqua One Distributed in Australia by Kong s Aust Pty Limited 48 Williamson Rd Ingleburn 2565 NSW Australia Distributed in New Zealand by Kong s NZ Limited 52 Glenlyon Avenue Greerton Tauranga New Zealand Distributed in Hong Kong by Kong s Aquarium Supplies Co Ltd No 31 3 F Thriving Industrial Centre 26 38 Sha Tsui Road Tsuen Wan Hong Kong Distributed in the UK by Kong s UK Limit...

Page 15: ...Instruction Version 30 10 06 ...

Reviews: