background image

Set Up Instructions

4. Remove the Power Head / Protein Skimmer 
Housing (6) from the Filter Box.
Please Note: This may be a tight fit. 

5. Connect the Flexible Tubing to the Outlet of 
the Power Head. Ensure it is connected 
correctly. 

6. Insert the Power Head into the Housing. You 
will notice there are 4 holes where the rubber 
feet on the Power Heads Base are intended to 
sit.

7. Feed the Power Cord through the Housing. 
You will notice the Power Cord Cutout (7) near 
the top of the Airstone Housing. 

8. At the top of the housing there is a blue 
O-ring. Lubricate this with an aquarium safe 
lubricant. This will improve the seal and allow 
the Housing to be removed easier when 
maintenance is required.

9. Slide the Power Head / Protein Skimmer 
Housing back into the Filter Box. Be sure the 
Power Cord from the Power Head is feed 
through the Power Cord Cutout. 

10. DO NOT FORCE the unit together. If it feels 
tight lift the Housing back out and try again. 

11. Place the Drip Tray back ontop of the Media 
Baskets and refit the Media Access Lid. 

Setting up the Overflow Box 

For the following section refer to Diagrams 1 & 
3 on pages 5 & 6 of this instruction booklet.

1. Position the MariSys in the stand / cabinet 
under the aquarium or to the side next to the 
stand.

2. Place the Overflow Box (8) on the rear or 
side of the aquarium. Initially the height of the 
box should be at its lowest setting. The two 
Adjusting Screws (9) on each side will allow for 
the Overflow Box to be raised or lowered. 

To lower the aquarium’s water level, turn the 
adjusting screws anti-clockwise, this will reduce 
the height of the Overflow Box To raise the 
water level in the aquarium, turn the adjusting 
screws clockwise to move the box back up. 

Setting up the Filter Media 

For the following section refer to Diagrams 1 & 
2 on pages 3,5 & 6 of this instruction booklet.

Locate and organise all parts before assembly.  
Familiarise yourself with the parts and where 
they fit. (Refer to the Quick Set Up Guide and 
Exploded View sheet) The only tools you will 
need to assemble your MariSys Filter are a 
flathead screwdriver, a utility knife and a tape 
measure.

1. Remove the Media Access Lid (1) from the 
top of the Filter Box (2), lift and remove the Drip 
Tray (3).   

2. Lift the handles and remove all of the Media 
Baskets (4) from the Filter Box and take them to 
the sink.

3. Ensure there is no soap or any other residue 
around the sink area.

4. Remove the Carbon Pillow and CeramiSub 
from the plastic bag, rinse them along with all of 
the other filter media under tap water.  

5. Refer to the diagram on page 4 for the 
correct placement of the media and the order in 
which they should be placed in the Filter Box. 

6. Return the Media Baskets to the Filter Box.

7. Do not replace the Drip Tray or Media Access 
Lid yet. 

Setting up the Power Head 

For the following section refer to Diagram 2 on 
page 5 of this instruction booklet.

1. Remove the Power Head (5) from the box 
marked PUMP.  

2. Check the Intake Elbow is firmly inserted and 
facing downwards.

3. Ensure your hand is dry and plug the Power 
Head in to ensure it is working. DO NOT stick 
fingers or inanimate objects into the pump if it 
does not work. Refer to the Maintenance 
section of this booklet for instruction on 
disassembling the unit.

7

Summary of Contents for MariSys 240

Page 1: ...MariSys 240 Complete step by step instruction booklet ...

Page 2: ...plug or receptacle does get wet do not unplug the appliance Disconnect the fuse or circuit breaker that supplies the power to the appliance then unplug and examine for presence of water in the receptacle 3 Close supervision is necessary when the appliance is used by or near children 4 Always unplug the filter from the electrical outlet when not in use before putting on or taking off parts before a...

Page 3: ...as been assembled This product is shipped to you in a factory sealed carton Should the product malfunction in any way or if the unit is damaged and requires replacement contact the retailer where the product was purchased for inspection Replacement Parts Filter Media Use Aqua One Genuine Spare Parts Only See your local Aqua One Dealer and look for the number listed below for the spare part you req...

Page 4: ...bon Pad Media Basket 1 Media Basket 3 Wool x 3 Activated Carbon Pillow Media Basket 2 Bio Balls CeramiSub Drip Tray Please Note This filter media set up above is a guide For more information regarding filter media please consult your Aqua One specialist 4 ...

Page 5: ...tein Skimmer Air Pump Fit a check valve if placed on the floor 12 Priming Pump 20 Check Valve 21 Air Control Valve 26 Protein Skimmer Height Adjuster 8 Overflow Box 2 Filter Box 19 Protein Skimmer Airline Connector 1 Media Access Lid 15 Water Bridge 27 Priming Chamber Duck Bill Outlet 28 Max 29 Min 14 V Joint 1 MariSys Complete System Diagram 1 5 ...

Page 6: ...Basket 3 CreamiSub Carbon Pillow Airstone Stop 5 Power Head Outlet Inlet Airstone Housing 25 Reaction Chamber Lid Waste Out 10 Water Level Adjuster 11 Screw Adjuster 9 Adjusting Screws 23 Protein Skimmer Collection Cup 7 Power Cord Cutout 4 8 Overflow Box 3 Overflow Box Diagram 3 2 MariSys Diagram 2 6 Power Head Protein Skimmer Housing 6 ...

Page 7: ...the adjusting screws anti clockwise this will reduce the height of the Overflow Box To raise the water level in the aquarium turn the adjusting screws clockwise to move the box back up Setting up the Filter Media For the following section refer to Diagrams 1 2 on pages 3 5 6 of this instruction booklet Locate and organise all parts before assembly Familiarise yourself with the parts and where they...

Page 8: ...e should be positioned about 1 5 2cm from the bottom of the Reaction Chamber The aquarium s water level can also be raised or lowered by adjusting the Water Level Adjuster 10 Raising the tube will cause the aquarium s water level to rise and lowering the Water Level Adjuster will cause the aquarium s water level to drop 3 Remove the pre filter pad rinse it under water and place back into the Overf...

Page 9: ...n wait 5 minutes If still too few turn the screw another quarter turn It is best to adjust slowly to achieve the desired level of bubbles B If there are too many bubbles and the Collection Cup is overflowing rapidly slowly close the Air Control Valve to achieve desired bubble flow 6 To further adjust and fine tune the Protein Skimmer loosen the Height Adjuster 26 located at the base of the Collect...

Page 10: ...d reconnect it to the system To ensure optimum filter performance routine maintenance should be performed monthly or less depending on size of tank amount of fish and number of daily feeding If the filter and media are neglected the filter media will become clogged and unable to collect waste material This can affect aquarium water quality and possibly the health of the tank inhabitants Grimy wast...

Page 11: ...Cleaning your Power Head Inlet Elbow Impeller Cover Lock Impeller Cover Impeller Blades Impeller Motor Outlet Base Rubber End Cap Ceramic Shaft O ring 11 ...

Page 12: ... Maintenance section in this instruction booklet WATER LEAKING AT FLEXIBLE HOSING CONNECTIONS 1 Disconnect Flexible Hoses from connectors on the MariSys and Overflow Box and clean connectors thoroughly with an Aqua One Double Ended Pipe Brush Reconnect and tighten hose clamps snugly 2 If the Flexible Hosing has slipped from original position remove and clean area then reconnect and tighten hose cl...

Page 13: ...mer Air Pump with new ones 3 Check air line for kinks 4 Check the Air Control Valve and Check Valve OVERFLOW BOX NOT FUNCTIONING 1 Check power supply and confirm Priming Pump is plugged in 2 No water in Overflow Box add water 3 Check Overflow Box for obstacles 4 Check Hosing and Tubing for kinks or obstructions PRIMING PUMP NOT RUNNING 1 Check power supply and confirm Priming Pump is plugged in 2 ...

Page 14: ...ed in Australia by Aqua One Distributed in Australia by Kong s Aust Pty Limited 48 Williamson Rd Ingleburn 2565 NSW Australia Distributed in New Zealand by Kong s NZ Limited 52 Glenlyon Avenue Greerton Tauranga New Zealand Distributed in Hong Kong by Kong s Aquarium Supplies Co Ltd No 31 3 F Thriving Industrial Centre 26 38 Sha Tsui Road Tsuen Wan Hong Kong Distributed in the UK by Kong s UK Limit...

Page 15: ...Instruction Version 30 10 06 ...