Doc. 12-7874-r06 (11/27/17)
63
TECHNICAL DATA
© Aqua Lung International, Inc. (2017)
ALTITUDE LEVELS
DISPLAY RANGE: METERS (FEET)
SEA
915 (0 to 3,000)
EL2
916 to 1,525 (3,001 to 5,000)
EL3
1,526 to 2,135 (5,001 to 7,000)
EL4
2,136 to 2,745 (7,001 to 9,000)
EL5
2,746 to 3,355 (9,001 to 11,000)
EL6
3,356 to 3,965 (11,001 to 13,000)
EL7
> 3,965 (13,000)
OXYGEN EXPOSURE LIMITS
(from NOAA Diving Manual)
PO2
(ATA)
MAX DURATION
SINGLE EXPOSURE
(MIN)
MAX TOTAL DURATION
24 HOUR DAY
(MIN)
0.60
720
720
0.70
570
570
0.80
450
450
0.90
360
360
1.00
300
300
1.10
240
270
1.20
210
240
1.30
180
210
1.40
150
180
1.50
120
180
1.60
45
150
Summary of Contents for i300C
Page 1: ...Aqua Lung International Inc 2017 Dive Computer Owner s Manual Doc 12 7874 r06 11 27 17 i300C...
Page 6: ...Doc 12 7874 r06 11 27 17 6 Aqua Lung International Inc 2017 GETTING STARTED...
Page 11: ...Doc 12 7874 r06 11 27 17 11 Aqua Lung International Inc 2017 DIVE FEATURES...
Page 16: ...Doc 12 7874 r06 11 27 17 16 Aqua Lung International Inc 2017 DIVE SURFACE MODE...
Page 31: ...Doc 12 7874 r06 11 27 17 31 Aqua Lung International Inc 2017 DIVE OPERATION...
Page 44: ...Doc 12 7874 r06 11 27 17 44 Aqua Lung International Inc 2017 GAUGE MODE...
Page 48: ...Doc 12 7874 r06 11 27 17 48 Aqua Lung International Inc 2017 FREE MODE...
Page 56: ...Doc 12 7874 r06 11 27 17 56 Aqua Lung International Inc 2017 REFERENCE...
Page 61: ...Doc 12 7874 r06 11 27 17 61 Aqua Lung International Inc 2017 TECHNICAL DATA...
Page 67: ...www aqualung com...