UPLOADING/DOWNLOADING DATA
As previously described (page 27), the i300C can be paired using the Bluetooth® feature. This requires a mobile
device with Bluetooth® running D software.
NOTE
: If a USB cable is connected to the i300C, Bluetooth® connection will be blocked or disabled.
Though any active downloads, uploads, or firmware updates using Bluetooth® will be allowed to finish
first.
Alternately, the i300C is configured with a Data Port located on the side of the module that enables it to be con
-
nected to a PC through a USB port using a special interface cable that is available as an optional accessory. The
USB Driver required for the interface system is downloadable from www.aqualung.com.
The Settings Upload portion of the program can be used to set/change the Gases, Set AL group (Alarms), Set
UTIL group (Utilities), and Set TIME group (Time/Date) using the same Interface System. The Mode settings must
be entered using the i300C button controls.
Information available for retrieval* (download) from the i300C to the PC Download portion of the program includes
items such as dive number, surface interval time, depth, dive time, start dates/time, lowest temperature, sampling
rate, set points, N2 Bar Graph, and ASC Bar Graph.
*FREE Dive information is only available using the PC Interface system.
The i300C checks for the presence of an interface device connection to the Data Port once every second* while in
Surface Mode.
*Checks are not made if the H2O ACT (water activation) contacts are wet.
Upon sensing an interface connection, the requesting device (PC) connects to the i300C. It is then prepared for
uploading settings or downloading data, which is initiated using the PC program. During the process there is a PC
countdown (2 minutes) screen displayed on the i300C.
Prior to attempting to download data from your i300C or upload settings to it, review the HELP section of the inter-
face program. It is recommended to print those sections of HELP that you consider appropriate for your interface
activities.
depth
sensor
PC interface
data port
PC COUNTDOWN
NOTE: The PC Countdown screen will
not appear if the cable is attached upside
down.
Summary of Contents for i300C
Page 1: ...Aqua Lung International Inc 2017 Dive Computer Owner s Manual Doc 12 7874 r06 11 27 17 i300C...
Page 6: ...Doc 12 7874 r06 11 27 17 6 Aqua Lung International Inc 2017 GETTING STARTED...
Page 11: ...Doc 12 7874 r06 11 27 17 11 Aqua Lung International Inc 2017 DIVE FEATURES...
Page 16: ...Doc 12 7874 r06 11 27 17 16 Aqua Lung International Inc 2017 DIVE SURFACE MODE...
Page 31: ...Doc 12 7874 r06 11 27 17 31 Aqua Lung International Inc 2017 DIVE OPERATION...
Page 44: ...Doc 12 7874 r06 11 27 17 44 Aqua Lung International Inc 2017 GAUGE MODE...
Page 48: ...Doc 12 7874 r06 11 27 17 48 Aqua Lung International Inc 2017 FREE MODE...
Page 56: ...Doc 12 7874 r06 11 27 17 56 Aqua Lung International Inc 2017 REFERENCE...
Page 61: ...Doc 12 7874 r06 11 27 17 61 Aqua Lung International Inc 2017 TECHNICAL DATA...
Page 67: ...www aqualung com...