![Aqua Lung i300C Owner'S Manual Download Page 19](http://html1.mh-extra.com/html/aqua-lung/i300c/i300c_owners-manual_2958535019.webp)
Doc. 12-7874-r06 (11/27/17)
19
DIVE SURFACE MODE
© Aqua Lung International, Inc. (2017)
PLAN
Pressing the SEL button while viewing the PLAN Lead-in screen accesses the dive planner mode. This mode
calculates dive depth and time limits. To do so, it accounts for any residual nitrogen, oxygen, surface intervals,
the programmed gas mix, and PO
2
alarm setting. Either NO DECO or O
2
MIN limits are displayed, depending on
whether nitrogen or oxygen levels will be the limiting factor. The time limit will display as 1-99 minutes, all times
greater than 99 display as 99.
NOTE: Depths exceeding the MOD (Maximum Operating Depth), if nitrox, or that have less than 1 min-
ute allowed dive time will not be displayed.
ADV
SEL
blank if CF
turned OFF
current PO
2
Alarm
setpoint, blank if FO2
is Air
% O
2
,
current
FO
2
setpoint
ADV
SEL
MOD
or O2 MIN
to increase
depth
exit to
Main Menu
next item in
Main Menu
LOG
Pressing the SEL button while viewing the LOG Lead-in screen accesses the dive log. The log stores Information
from the latest 24 DIVE and/or GAUGE mode dives for viewing.
> If no dives are recorded, the message NONE YET 0 DIVE will be displayed in the log.
> After exceeding 24 dives, the most recent dive is stored while the oldest is deleted.
> Dives are numbered from 1 to 24 starting each time a dive is activated in either Dive (or Gauge) mode. After
the post dive 24 hour period has elapsed and the unit shuts off, the first dive of the next activation period will be
recorded as dive #1.
> I n the event that dive time (DIVE-T) exceeds 999 min, the data at the 999 interval is recorded in the Log upon
surfacing of the unit.
NOTE: New data will automatically overwrite the oldest data in memory when the memory becomes
full. The i300C Log and PC Download data is stored separately in different partitions of the memory.
The Log only stores a short summary of each dive. Alternately, the PC Download function stores much
larger files for each dive. For this reason, it is normal to see dives stored in the i300C's onboard Log
that have already been overwritten in the PC Download Partition. If you do not remember to log or
download your dives, they will be lost when the memory overwrites. See the PC Download section of
this manual for instructions on downloading dives.
ADV
SEL
ADV
SEL
date
of dive
time dive
started
next dive
recorded
enter dive
record
access
planner
next item in
Main Menu
access
log
dive #
blank if DIVE,
GAU for GAUGE dive,
VIO for a violation dive
LOG PREVIEW
LOG LEAD-IN
Summary of Contents for i300C
Page 1: ...Aqua Lung International Inc 2017 Dive Computer Owner s Manual Doc 12 7874 r06 11 27 17 i300C...
Page 6: ...Doc 12 7874 r06 11 27 17 6 Aqua Lung International Inc 2017 GETTING STARTED...
Page 11: ...Doc 12 7874 r06 11 27 17 11 Aqua Lung International Inc 2017 DIVE FEATURES...
Page 16: ...Doc 12 7874 r06 11 27 17 16 Aqua Lung International Inc 2017 DIVE SURFACE MODE...
Page 31: ...Doc 12 7874 r06 11 27 17 31 Aqua Lung International Inc 2017 DIVE OPERATION...
Page 44: ...Doc 12 7874 r06 11 27 17 44 Aqua Lung International Inc 2017 GAUGE MODE...
Page 48: ...Doc 12 7874 r06 11 27 17 48 Aqua Lung International Inc 2017 FREE MODE...
Page 56: ...Doc 12 7874 r06 11 27 17 56 Aqua Lung International Inc 2017 REFERENCE...
Page 61: ...Doc 12 7874 r06 11 27 17 61 Aqua Lung International Inc 2017 TECHNICAL DATA...
Page 67: ...www aqualung com...