36
Quality for Professionals
15.3
Amphenol Molex sensor (item no.: 00410-2-006)
Connection
12-pin connector on the control module
Scope of delivery:
1 sensor cable (Amphenol)
Cable length:
1200mm
A connection from the tractor to the control module can be made
using the 7-pin cable. Signals pass through this cable from the
tractor to the control module (DIN 9684 standard). Only the
hoist signal (working position) is transmitted from the tractor to
the control module via this. This signal opens and closes the
shutter automatically. For coupled tillage implements, the sensor
can be installed on the chassis, because the hoist is not being
used.
Because of the hoisting system signal, you do not need to
manually operate the control module, even when making turns.
In order to rotate the working position, the
button and
button must be
pressed at the same time.
This appears on the display:
Note: On some tractors, the hoisting system signal is not available as standard.
The slider only opens when the spreading disc is running!
Fig.: 18
Fig.: 19
Three-step signal
inverted!