4
200
145
2168 / 2768 / 3368
360
ENGLISH
The level of noise emission of operator HOME 60, referred
to the work station, is 52 dB(A).
These instructions apply to model
APRITECH HOME 60
.
The HOME 60 automated systems make it possible to automate
balanced sectional doors of single garages for residential use.
They consist of an electro-mechanical operator, electronic
control unit and courtesy light built into a single unit. This unit is
fitted to the ceiling and opens the door by means of a transmission
chain or belt.
The system is non-reversing and, therefore, the door locks
mechanically when the motor is not operating and, consequently,
no lock is necessary; two manual releases, one on the inside and
one on the outside (optional) make it possible to move the door in
case of a power cut or fault.
The operator is supplied with an electronic device that detects the
presence of an obstacle that would hinder door movement - the
device prevents crushing or lifting.
This instruction refers to the operator with chain drive, but the same
procedures, regulations and application limits apply also to the belt
driven operator.
The HOME 60 automated systems were designed and built for
indoor use and to control vehicle access. Do not use them for
any other purpose.
1 DIMENSIONS
2 TECHNICAL SPECIFICATIONS
AUTOMATED SYSTEM HOME 60
3 ANCILLARY ELECTRICAL EQUIPMENT
Cable 2 x 0.5 mm
2
(TX photocell)
Cable 4 x 0.5 mm
2
(RX photocell)
Power pipe (230V)
Low voltage pipe
Cable 2 x 1.5 mm
2
(power)
Fig. 2
Dimensions in mm.
Fig. 1
Power supply (V ~ / 50 Hz.)
230
Electric motor (Vdc)
24
Maximum absorbed power (W)
220
Thrust force (N)
600
Type of use
continuous
Maximum dimensions from ceiling (mm)
35 (Fig. 4)
Courtesy light (V ~/W)
230 / 40 max.
Courtesy light timer (sec)
120
Standard speed with no-load carriage (m/min)
6,6
Slow speed with no-load carriage (m/min)
3,8
Carriage deceleration speed (m/min)
1,3
Noise at standard speed (dB(A))
52
Travel length at deceleration
varies according to set-up
Intrinsic safety device
Category 2
Maximum sectional door width (mm)
5000
Maximum sectional door height (mm)
(see useful travel)
Sliding guide useful travel (mm)
1900 - 2500 - 3100
Protection class
for indoor use only (IP20)
Operating ambient temperature (°C)
-20 / +55
Prepare the electric system in keeping with the instructions in the
chapter entitled “Warnings for the installer”.
When you have finished installing, check if any external pipes or
cables can come into contact with moving parts.
Install the fixed control points at a minimum height of 150 cm, clear
of the door movement area, but in a position enabling visual control
of that area.
Summary of Contents for Home 60
Page 1: ...HOME 60...
Page 111: ......