5
ENGLISH
- The structure of the door must be suitable for fitting automation.
In particular, check that the door dimensions conform to those indi-
cated in the technical specifications, and that it is sufficiently sturdy.
- Check if the door conforms to standards EN12604 and EN12605.
- As it moves, the door must not encroach public areas
dedicated to pedestrian or vehicular transport.
- Check the efficiency of the door bearings and joints.
- Make sure that the door is friction-free. If necessary clean and
lubricate the guides with silicone based products, but do not use
grease, and, in any event, follow the manufacturer’s instructions.
- Check correct balance and if the opening mechanical stops have
been installed.
- Remove the door’s existing closing mechanism to ensure the door
is closed by the automated system.
- Make sure there is a clearance of at least 35 mm between the
ceiling and the highest sliding point of the door (Fig.4).
- Check if the upper guide roller of the sectional door is in the hori-
zontal part of the guide while the door is closed (fig. 5).
Fig. 3
Ceiling lamp
Rear door
Courtesy light
Plastic housing for HOME 60 operator
Rear fitting
Sliding guide
Drive carriage
Release knob
Door fitting bracket
Transmission unit
Front fitting and chain tensioner
Front fitting bracket
Fig. 5
Fig. 4
4 DESCRIPTION