![APRITECH Home 60 Installation Manual Download Page 29](http://html1.mh-extra.com/html/apritech/home-60/home-60_installation-manual_2956778029.webp)
11
ENGLISH
Fig. 26
9 COURTESY LIGHT
Fig. 27
OPEN A
OTHER SAFETY DEVICES
10 CONNECTIONS
The automated system stopped and at rest is indicated in
bold for each input.
STOP
During the opening manoeuvre, the
anti-crushing device causes an immediate
stop. During the closing manoeuvre, it opens
the
door.
If, during closure, an obstacle is detected more than
three consecutive times, the automated system
considers this distance as the new closing contact point
and goes into closed status. To restore the correct
positions, remove the obstacle and command a new
cycle: at the next closure, the automated system will
advance at low speed until it detects the contact point.
LD
Meaning
OFF
ON
1
Input status OPEN
Not enabled
Enabled
2
Input status STOP
Enabled
Not Enabled
3
Input status FSW
Safety devices engaged
Safety devices disengaged
FLASHING LAMP
- The courtesy light stays lighted for 2 minutes after the end of the
manoeuvre (cannot be modified).
IMPORTANT: Before attempting any work on the board
(connections, maintenance), always cut off power.
- To prevent any electric noise whatever, use separate sheaths for
powering the network, signals and accessories.
- The HOME 60 operator has a cable with a two-pole plug for 230
Vac power supply.
- To connect the external controls, safety devices and signals, break
open the pre-holed element (Fig. 26 ref.
).
- To connect the safety edge (see par. 18.3), break open the pre-
holed element (Fig. 26 ref.
).
- Make the electrical connections, referring to Fig. 27.
If the
STOP
input is not used, jumper connect the input to
the terminal
.
If the photocells are not used, connect the
FSW
input to terminal
-TX FSW
.
Input status LEDS