background image

19

 -

English

Installation

1

2

VALUES IN MILLIMETRES

L

A

B

C

Y Max.

130 140 275

90

1200

÷

3000

C1

AP030008

C2

C3

3

2

4.1     PREPPING FOR THE REAR MOUNTING
4.1.1  Operator fi xed on iron posts

If the gate supporting posts are made of iron, it is necessary to 

fi

 t a reinforcing plate for welding the rear operator mounting.

Perfectly clean the welding zone for the rear mounting with the special tool (

C2

 pos.

1

); make sure to remove any traces of paint 

or zinc coating.
Position the reinforcing plate (

C3

 pos. 

2

) in the rear mounting welding zone and weld it on the column, covering it from edge to edge.

The size of the reinforcing plate must be in proportion to the size of the column.

Warning

!

•  If the size of the column allows for it, use the Aprimatic 

standard plate provided.

4.1.2  Operator 

fi

 xed on wooden posts

If the gate supporting posts are made of wood, it is necessary to 

fi

 t 

a reinforcing plate on the column, covering it from edge to edge, in 
the rear mounting welding zone. The plate shall be 

fi

 xed 

fi

 rmly on the 

column by means of 

fi

 xing screws (

C4

).

The size of the reinforcing plate must be in proportion to the size 
of the column.

Warning

!

•  If the size of the column allows for it, use the Aprimatic 

standard plate provided.

4.1.3  Operator 

fi

 xed on masonry posts

If the supporting posts for the gate leaves are made of masonry, 

fi

 x 

the special metal plate complete with anchor bolts used to weld on 
the rear mounting of the operator to each of them.  

Preparing the insets

If mounting insets have to be made in the posts for the rear operator 
mounting with metal plates, the measurements shown in fig.

C6 

must be adhered to.

Warning

!

Remember that the inset is necessary when the distance between 
the edge of the post and the centre of rotation of the gate leaf is 
greater than the distance 

Y

 (C1), or when the gate leaf is anchored 

to a continuous wall.

Fixing the anchoring plates

Fig. C5 shows some 

fi

 xing examples by means of different types 

of plates:

A   -

   Plate with hooked 

fi

 tting

B   -

   Plate with stud bolts, either glued or pressure-

fi

 tted

C   -

   L-plate with stud bolts, either glued or pressure-

fi

 tted

C5

C4

min 5 mm

*

 CUT TO MEASURE

(not supplied by APRIMATIC)

min 5 mm

min 5 mm

B

APRIMATIC

(standard)

A

APRIMATIC

(optional)

C

*

1) Wing rotation axis
2) Operator centre of rotation

Summary of Contents for ZT4 C

Page 1: ...ses 20 4 2 Fixing the rear operator mounting 21 4 3 Temporary installation of the operator 21 4 4 Positioning the front operator mounting 22 4 5 Final installation of the operator 23 4 5 1 Mechanical...

Page 2: ...n the basis of the characteristics and dimensions of the element to be operated Caution The choice of the most suitable type of automation assures an efficient operation of the unit and minimises the...

Page 3: ...the operator power cable with a sheath if necessary do this before connecting the cable to the junction boxes Warning Every operator comes complete with a pickup capacitor During installation connect...

Page 4: ...rule the ideal point is always in the strongest area where the fixing of the gate leaf has the least effect If there is not a broad strip of steel in the gate framework then a suitable support needs...

Page 5: ...SAG 285 14 7 USAG 285 17 4 INSTALLING THE OPERATOR 4 0 POSITIONING THE MOUNTINGS The following table C1 indicates the recommended data for defining the position of the operator mountings in relation t...

Page 6: ...ixing screws C4 The size of the reinforcing plate must be in proportion to the size of the column Warning If the size of the column allows for it use the Aprimatic standard plate provided 4 1 3 Operat...

Page 7: ...nsert the mesh sheaths C8 pos 3 into the holes and inject the quick dry glue C8 pos 4 see attached instructions for application method and quantity If the B type plate is used Insert the stud bolts C8...

Page 8: ...ly protected from weld residues When the welded zone has cooled down apply a coat of anti rust paint 4 3 TEMPORARY INSTALLATION OF THE OPERATOR Temporarily mount the operator to find the correct fixin...

Page 9: ...the strengthening plate is especially important with gate leaves made from thin sheet steel When cleaning the mounting zone for the operator front mounting remove the operator and protect it from fly...

Page 10: ...the movement this should be done very slowly otherwise the operators will take in air and consequently will have to be bled Open and close the gate leaf to check that the operator can move freely wit...

Page 11: ...crewdriver turn the control valves clockwise to increase the pressure and counter clockwise to reduce it Adjust both opening silver E8 pos 2 and closing pressure gold E8 pos 1 Caution The opening thru...

Page 12: ...sun for a long period with the gate closed check that the operator piston is not in the fully advanced position i e with the rod completely out Screw the pressure setting valve clockwise par 5 E8 pos...