1. 

CHARACTERISTICS OF THE OPERATOR

1.0     GENERAL CHARACTERISTICS

  

ZT 4

 is a 

hydraulic swing gate operator

, specially designed for residential use.

•    The ZT 4 operator, if installed correctly, conforms to the current safety standards.
List of versions:

C:

    Hydraulic lock for closing only  (with lock inaccessible when the gate is open)

SF:

   No hydraulic lock - braking action (the gate leaf can be moved by hand with a minimum of resistance, if moved slowly; there is also a 

release device to facilitate opening  -needs an electric lock)

   The 

C

 version, with hydraulic closing lock, does not require the use of the electric lock and keeps gate leaves of less than 1.8 

m in closed position.

 

   The emergency release (to be used in the event of a power failure) is safe to use and easily manoeuvrable and enables the user to move the 

gate by hand using the triangular key provided. The release is easily accessible via a hatch on the upper cover of the operator.

   Safety against entrapment risks is guaranteed by sensing valves, settable during installation.

1.1     TECHNICAL DATA

Warning

!

The noise le

vel of the above models, referred to the working of the operator, independently of the gate leaf and the post, falls 

within the maximum limits set by EEC standards.

1.2     CHOOSING THE TYPE OF AUTOMATION

Before mounting, choose the type of automation on the basis of the characteristics and dimensions of the element to be operated. 

Caution

  The choice of the most suitable type of automation assures an effi cient operation of the unit and minimises the possibility 

of failures.

Warning

!

•  The versions listed above are also recommended for use with solid gate leaves (with the operator inaccessible when 

the gate is open). 

•    The C version model, suitable for use in windy areas, must not be fi tted to gate leaves of up to 1.8 m.

Warning

!

The peripheral speed of the gate leaf must always fall within the limits of the current safety regulations. Also, it is important 
to avoid the use of high-speed operators on wide gate leaves, as this could cause the leaves to bang violently against the 
gate stop (see the “Technical Data” table).     

Characteristics / Preliminary operations

230 V±10% 50 Hz

ZT4 SF

CARACT

É

RISTIQUES

Single-phase system voltage 

Power absorption

Mean pressure 

Thrust force at 10 bar

Traction force at 15 bar

Rod retraction time (max. stroke) 

Rod extension time

Max leaf length

Min leaf length

Operating temperature range

Max distance between centres for mounting 
holes with fully extended rod 

Max stroke - standard arm

Weight with oil

Oil quantity

Oil type

250W

250W

30 bar

-20° / + 70°C

8 Kg

Aprimatic Oil HC13

ZT4 C

230 V±10% 50 Hz

30 bar

962 N

962 N

1140 N

1140 N

17,5 sec

17,5 sec

21,5 sec

21,5 sec

1,8 m

3 m

1,2 m

1,2 m

-20° / + 70°C

1002 mm ± 5 

1002 mm ± 5 

270 mm

270 mm

8 Kg

0,6 lt.

0,6 lt.

Aprimatic Oil HC13

Protection degree

IP 55

IP 55

1060

698

274

A (mm)

B (mm)

C (mm)

ZT 4

90

97,

5

C

A

B

70

Summary of Contents for ZT4 C

Page 1: ...ses 20 4 2 Fixing the rear operator mounting 21 4 3 Temporary installation of the operator 21 4 4 Positioning the front operator mounting 22 4 5 Final installation of the operator 23 4 5 1 Mechanical...

Page 2: ...n the basis of the characteristics and dimensions of the element to be operated Caution The choice of the most suitable type of automation assures an efficient operation of the unit and minimises the...

Page 3: ...the operator power cable with a sheath if necessary do this before connecting the cable to the junction boxes Warning Every operator comes complete with a pickup capacitor During installation connect...

Page 4: ...rule the ideal point is always in the strongest area where the fixing of the gate leaf has the least effect If there is not a broad strip of steel in the gate framework then a suitable support needs...

Page 5: ...SAG 285 14 7 USAG 285 17 4 INSTALLING THE OPERATOR 4 0 POSITIONING THE MOUNTINGS The following table C1 indicates the recommended data for defining the position of the operator mountings in relation t...

Page 6: ...ixing screws C4 The size of the reinforcing plate must be in proportion to the size of the column Warning If the size of the column allows for it use the Aprimatic standard plate provided 4 1 3 Operat...

Page 7: ...nsert the mesh sheaths C8 pos 3 into the holes and inject the quick dry glue C8 pos 4 see attached instructions for application method and quantity If the B type plate is used Insert the stud bolts C8...

Page 8: ...ly protected from weld residues When the welded zone has cooled down apply a coat of anti rust paint 4 3 TEMPORARY INSTALLATION OF THE OPERATOR Temporarily mount the operator to find the correct fixin...

Page 9: ...the strengthening plate is especially important with gate leaves made from thin sheet steel When cleaning the mounting zone for the operator front mounting remove the operator and protect it from fly...

Page 10: ...the movement this should be done very slowly otherwise the operators will take in air and consequently will have to be bled Open and close the gate leaf to check that the operator can move freely wit...

Page 11: ...crewdriver turn the control valves clockwise to increase the pressure and counter clockwise to reduce it Adjust both opening silver E8 pos 2 and closing pressure gold E8 pos 1 Caution The opening thru...

Page 12: ...sun for a long period with the gate closed check that the operator piston is not in the fully advanced position i e with the rod completely out Screw the pressure setting valve clockwise par 5 E8 pos...