ENGLISH
3. INSTALLATION
Fix the appliance directly to the wall using the
holes on the container body.
Perforate the container and run the cables
through the hole using cable clamps.
Connect the cables to the terminals, then insert
the card and place the cover.
4. WIRING DIAGRAMS
Warning
!
Connect Phase and Neutral Wire of the mains supply as shown in the picture.
Controls and available inputs
Channel 1 Command
: connect the NO contact of a device such as a pushbutton used to send an activation signal
to the load connected to the channel 1 output between the terminals 2 and 6.
Channel 2 Command
: connect the NO contact of a device such as a pushbutton used to send an activation signal
to the load connected to the channel 2 output between the terminals 2 and 5.
Information
The appliance comes complete with antenna. If the range is not suffi cient, an external antenna can be connected
to the special terminals as shown.
Terminal board for connecting mains
supply circuit and loads
fi g. 4.1
5. MEMORY MANAGEMENT
The information regarding remote controls and operation selections are stored in the module memory.
To restore the factory-set confi guration and erase all remote controls previously stored in the module memory,
proceed as follows:
Turn off the module.
Turn the module on again while holding the clear key SW3 pressed until the buzzer will turn off.
Wait about 10 seconds until the module beeps once signalling that the clearing phase is completed.
6. REMOTE CONTROLS MANAGEMENT
6.1 FIRST PROGRAMMING
Turn on the module and wait until it beeps once, then:
1. Press keys 1-4-5-8 simultaneously if you are using a TR14, or press all keys if you are using a TR2 or a TR4, until
a short beep followed by a continuous sound will be emitted: the learning phase is in progress.
2. Now press any key on the transmitter: the buzzer will turn off for a short time, then turns on again to confi rm
that the remote control has been stored in the module memory.
After the fi rst learning, it is possible to store other remote controls by repeating steps 1 and 2 until the sound
alarm remains activated.
The learning phase ends either at the pressure of the clear key SW3 or automatically about 25 seconds
after the last storage.
When one or more remote controls are stored in the module memory, a signal transmitted by key
is
interpreted as a “Channel 1” command, a signal transmitted by key
as “Channel 2” command.
The appliance can also receive a Centralized Activation or Deactivation command via radio (equivalent to those
via cable). These two commands are not activated in the standard confi guration: to modify and/or complete the
standard keys - RF commands confi guration, read par.
9
.
Information
To prevent an accidental programming, turn off other appliances within the range of the remote control you are
using if such appliances have still to be programmed.
fi g. 4.2
Terminal board for
connecting controls
Key 1
Key 2
Key 3
Key 2
Key 4
Key 1
4
4
fi g. 6.1
Summary of Contents for ADI R230E