(1) SELECT A MOUNTING LOCATION
If installing the thermostat alone…
• Mount on an interior wall, in a frequently occupied space.
• Keep the thermostat 18" from an outside wall.
• Mount the thermostat approximately 5 feet above the floor.
Height requirements are different for compliance with the
Americans with Disabilities Act (ADA) – 48" maximum height
for forward reach and 54" maximum height for side reach.
• Thermostat can be mounted to a vertical junction box (j-box).
•
DO NOT
mount the thermostat:
– behind doors, in corners or other dead air spaces.
– in direct sunlight or near lamps, appliances or other
sources of heat.
– on an outside wall or wall exposed to an unconditioned
space (i.e. garage).
– in the flow path of a supply register, in stairways or near
outside doors.
– on a wall where concealed pipes or ductwork could
influence the sensor.
– near sources of electrical interference such as arcing
switch contacts.
If installing an indoor temperature sensor…
• Mount the thermostat where it can be readily accessed.
Note that the backlighting illuminates whenever a button
is pressed.
• Thermostat can be mounted on a vertical junction box (j-box).
•
DO NOT
mount the thermostat where the operating range
temperatures will be exceeded (i.e. attic or unventilated
equipment room).
• Mount the sensor in the same location as if installing a
thermostat alone.
Summary of Contents for 8570
Page 13: ... 9 Diagram 1 Single Stage Furnace and AC ...
Page 14: ... 10 Diagram 2 Two Stage Furnace and AC ...
Page 15: ... 11 Diagram 3 Two Stage Roof Top Unit ...
Page 16: ... 12 Diagram 4 Boiler with AC ...
Page 17: ... 13 Diagram 5 Radiant Floor 1st Stage Heat with Furnace 2nd Stage Heat and AC ...
Page 18: ... 14 Diagram 6 Single Stage Heat Pump ...
Page 19: ... 15 Diagram 7 Two Stage Heat Pump ...
Page 22: ...CIR GND IDS ODT ZA ZB C Figure 7 18 ...
Page 26: ... 22 CIR GND IDS ODT ZA ZB C Figure 9 ...
Page 40: ...DP 10006198 01 05 B2203358B Printed in U S A P O BOX 1467 MADISON WI 53701 1467 ...