- 5 -
(3) MOUNT THE THERMOSTAT BASE TO THE WALL
1. Place the wire opening in the base over the wire entry
hole in the wall. Level the base (for appearance only)
and mark the screw locations. See
Figure 4
.
2. Use the supplied screws and wall anchors to mount
the thermostat to the wall. It is recommended that wall
anchors be used for installation to drywall/sheet rock.
• Drill a 3/16" hole for wall anchors.
• Drill a 3/32" starter hole for screws only.
3. For junction box mounting, screws are field supplied.
The thermostat can be installed on a vertical j-box.
4. Seal the wire entry hole(s) with caulk, drywall putty
or insulation to prevent drafts from inside the wall
cavity from affecting thermostat performance.
CIR
GND
IDS
ODT
ZA
ZB
C
W2
W1
RH
R
RC
G
Y1
Y2
B
O
I
+
I
-
CAUTION
Minimize wire entry hole size and seal the hole – drafts from inside the wall could affect temperature readings.
Figure 4