- 2 -
Figure 1
and the table show the number of wires that must be available at the thermostat in stand-alone thermostat systems (i.e. not as
part of an Aprilaire
®
Model 6504 Intelligent Zone System).
Figure 1
shows optional connections to both an outdoor temperature sensor and
an Aprilaire
®
Automatic Humidifier Control (AHC), but only one or the other can be used. All wire is standard 18-24 gauge thermostat cable.
When this thermostat is connected to a Model 6504 as
shown in
Figure 2,
only one four-wire cable need be run
from the thermostat to the Model 6504. Use standard
18-24 gauge thermostat cable.
OPTIONAL –
AUTOMATIC
HUMIDIFIER
CONTROL
(AHC)
HVAC
EQUIPMENT
MODEL 8570
THERMOSTAT
SEE
TABLE
2-WIRES
2-WIRES
2-WIRES
OPTIONAL –
OUTDOOR
TEMPERATURE
SENSOR
OPTIONAL –
INDOOR
TEMPERATURE
SENSOR
MODEL 8570
THERMOSTAT
MODEL 6504
4-WIRES
Application
# Wires
Diagram (Page)
Single-Stage Furnace/AC
5
1 (9)
Two-Stage Furnace/AC
7
2 (10)
Two-Stage Roof Top Unit
7
3 (11)
Boiler w/AC (2-transformer)
6
4 (12)
Radiant 1st Stage Heat,
6
5 (13)
Furnace 2nd Stage and AC
Single-Stage Heat Pump
6
6 (14)
Two-Stage Heat Pump
8
7 (15)
WIRE REQUIREMENTS
Figure 1 – Thermostat Wire
Figure 2 – Model 6504 Wire
Summary of Contents for 8570
Page 13: ... 9 Diagram 1 Single Stage Furnace and AC ...
Page 14: ... 10 Diagram 2 Two Stage Furnace and AC ...
Page 15: ... 11 Diagram 3 Two Stage Roof Top Unit ...
Page 16: ... 12 Diagram 4 Boiler with AC ...
Page 17: ... 13 Diagram 5 Radiant Floor 1st Stage Heat with Furnace 2nd Stage Heat and AC ...
Page 18: ... 14 Diagram 6 Single Stage Heat Pump ...
Page 19: ... 15 Diagram 7 Two Stage Heat Pump ...
Page 22: ...CIR GND IDS ODT ZA ZB C Figure 7 18 ...
Page 26: ... 22 CIR GND IDS ODT ZA ZB C Figure 9 ...
Page 40: ...DP 10006198 01 05 B2203358B Printed in U S A P O BOX 1467 MADISON WI 53701 1467 ...