CSP-SNv Capacitor Charging Unit Operation
Manual
CSP-CSPSNV-8000/3
_______________________________________________________________________________________________
__________________________________________________________________________________________________________
Page
54
of
56
Fault Flags
Format is 32-bit hex long word.
All fault flags are logged. Bit descriptions below:
e.g. for fault flags 0x00000001, 1 is HV OFF LATCH with no other faults (user ended
operation with HV OFF key).
POWER SUPPLY INTERRUPTED FAULT is assumed if all fault flags are zero.
BIT
DESCRIPTION
0
HV OFF LATCH
1
INTERLOCK LATCH
2
FAULT LATCH
3
HV FAULT LATCH
4
KEY IN TIMEOUT FAULT
5
HV SHORT CIRCUIT FAULT
6
HV OPEN CIRCUIT FAULT
7
HV CHARGER SUMMARY FAULT
8
HV CHARGER LOAD FAULT
9
HV CHARGER OUTPUT FAULT
10
HV SPARE FAULT
11
TA FAULT
12
TIN FAULT
13
TOUT FAULT
14
HV CONNECTOR INTERLOCK FAULT
15
TOP COVER INTERLOCK FAULT
16
THYRISTOR TEMPERATURE INTERLOCK FAULT
17
SPARE INTERLOCK FAULT
18
EMERGENCY STOP INTERLOCK FAULT
19
EMERGENCY STOP SWITCH FAULT
20
INTERLOCK BOARD FAULT
21
MCU FAULT
22
CPLD FAULT
23
LCD FAULT
24
EEPROM FAULT
25
LOW MAINS FAULT
26
REMOTE UNIT FAULT