CSP-SNv Capacitor Charging Unit Operation
Manual
CSP-CSPSNV-8000/3
_______________________________________________________________________________________________
__________________________________________________________________________________________________________
Page
27
of
56
Operation
The operation mode displays system settings together with operational feedback of
system status.
When HV is OFF the system continues to monitor system status.
The top left panel provides the status of the High Voltage (HV), HV status is also
displayed by the HV ON LED and HV ON // HV OFF Switch LEDs.
“Vkey” is the output high voltage level prior to key trigger.
“PSU” indicates status of the internal HV charger module. If a PSU fault occurs the HV
FAULT indicator is ON.
PSU Status Description
Ok
Ok
O/P
Load
Summ
HV Level Fault detected.
Load Fault, internal fault HV Capacitor.
Summary Fault, internal fault Low VAC, temperature, output over
voltage detected.
“Load” indicates status of the load (sound
source). The system monitors the output
current and voltage shot by shot to check for over-current condition (short-circuit) or
open-
circuit condition. The Load fault type is displayed if detected. If a “Load” fault
occurs the HV FAULT indicator is ON.
The HV ON switch is only active in OPERATION MODE. To enable HV
operation, the HV ON button must held on for 3 seconds.
Interlock
Fault:
No
EOC
HV: ON
Vkey:
3950v
PSU:
Ok
Load:
Ok
CSP:
Ok
Settings
Power: 1250J
Level: High
Key:
Int
F/D:
0us
Rate: 1500ms
AVIP: 75%
F/F: Off
L/R: Local
Tca: 29°C
Tco: 16°C
Teo: 30°C