CSP-SNv Capacitor Charging Unit Operation
Manual
CSP-CSPSNV-8000/3
_______________________________________________________________________________________________
__________________________________________________________________________________________________________
Page
48
of
56
Appendix A
–
CSP Firmware Upgrade
Requirements
•
PC with RS232 serial port & Hyperterminal
•
RS232 cable (not crossover type)
Procedure
1.
Ensure CSP is turned off.
2.
Connect RS232 cable between PC serial port & CSP front panel COM port.
3.
Configure Hyperterminal for:
115200 baud
8 data bits
1 stop bit
No parity
No flow control
4.
Whilst holding front panel button, turn on CSP.
5.
Check FAULT indicator is on. Check LCD is blank & LCD backlight is off. Check HV
OFF/RESET switch indicator is on. These checks indicate system is in bootloader
mode. Hyperterminal should display the following: