background image

User Manual: Multispot GII-HQ5020

    

                                       

 

V2.00 (08-2015)                                                                                                                                                

18

 

Please note that above speed levels are only applicable to patterns SP0….SP08. For 

the strobe patterns, the following speed table applies: 

 

Setting Speed 

S2L 

Beatflash function: one flash per sound trigger (Strobe-to-Sound) 

SL1..SL25 

Strobe speed 1 Hz...18Hz 

  

Choosing “S2L” activates the “Sound-to-Light” function shown by illuminating the “S” 

symbol in the display and displaying “S2L”. The speed is now being driven by the beat 

of the music taken up by the built-in microphone.  

 

Once the speed level is set or the S2L-function chosen and no changes done the 

display will return to show 

“SP0”…”SP12”

 after 5 seconds. The same happens if the 

pattern preset is changed by the left/right arrows, in this case the speed setting mode is 

left immediately and the speed will remain as last set. 

 

■ FADE PATTERNS 

 

In this mode you will only find soft fade patterns. Press the MODE button until the 

display shows 

“FPxx” 

whereas xx stands for numbers 00 until 07. The available 

patterns are defined as follow: 

 

Pattern Steps 

Pattern  Steps 

FP0 red-green 

FP4  candy-lime 

FP1 blue-green 

FP5  candy-blue 

FP2 blue-pink-red 

FP6  candy-aqua-turquoise 

FP3 yellow-lime-red 

FP7  red-yellow-green-turquoise-blue-candy 

 

Use the left/right arrows to change the pattern between any of the 8 presets, the display 

shows 

“FP0”…”FP07” 

accordingly and will remain to show unless the speed function is 

used. Use the +/- button to change the speed level. The first touch of the + or - button 

changes the display, now showing the speed level 

”SL00”…”SL25” 

representing the 

following speed levels: 

 

Setting Speed 

Setting  Speed 

SL0 

1 loop per 960 seconds 

SL13 

1 loop per 3 seconds 

SL1 

1 loop per 480 seconds 

SL14 

1 loop per 2 seconds 

SL2 

1 loop per 360 seconds 

SL15 

1 loop per 1,5 seconds 

SL3 

1 loop per 240 seconds 

SL16 

1 loop per 1,25 seconds 

SL4 

1 loop per 120 seconds 

SL17 

1 loop per 1 second 

SL5 

1 loop per 80 seconds 

SL18 

1,2 loops per second 

SL6 

1 loop per 40 seconds  

SL19 

1,4 loops per second 

SL7 

1 loop per 20 seconds  

SL20 

1,6 loops per second 

SL8 

1 loop per 12 seconds 

SL21 

1,9 loops per second 

SL9 

1 loop per 10 seconds  

SL22 

2,2 loops per second 

SL10 

1 loop per 8 seconds 

SL23 

2,5 loops per second 

User Manual: Multispot GII-HQ5020

    

                                       

 

V2.00 (08-2015)                                                                                                                                                

7

 

Before you start to change the connectors, please make sure that: 

  yourself or the person in charge has the relevant experience in safe work methods 

for electrical equipment service and maintenance.  

  the unit is disconnected from any AC source. Please note that this also applies to 

the unit’s AC output, since being connected by the AC output to other units which 

are still under AC supply, will still supply power to the unit.  

  the unit is completely dry, and at room temperature.  

  the location chosen to exchange the connectors does not have more than 40% 

relative humidity and the temperature during the exchange does not exceed 40 

degrees Celsius. These parameters are important to avoid later condensation of 

the water contained in the environmental air when the unit works at lower outside 

temperatures. 

  the screw driver used to dismantle and re-assemble the unit is properly matching 

the screws to avoid any damage to the screws. This will require a 4mm HexInsert 

screw driver.  

  the screw driver has an in-built torque measurement or you have other torque-

measurement devices on hand to make sure that screws are fastened with the 

right torque during re—assembly.   

 

To expedite the connector change, you will need  Multiform’s outdoor conversion kit for 

this unit, which is available from your distributor. Further, you will also need to have the 

suitable cable material on hand, which ideally is 

 

  Rubber AC cable of at least 3x1.5sqmm cross-section, with outer diameter of 

not less than 6mm, and not more than 9mm.  

  DMX signal cable, 2-wire+shield, with outer diameter of not less than 6mm, 

and not more than 9mm.  

  Matching wire termination sleeves. 

 

Reliability risk:

 Using cable material of unsuitable outer diameter or 

with insufficient flexibility  of its outer tubing may defeat the waterproof 

capabilities of the fixture and may void any warranty.  

 

The conversion kit itself contains: 

  The outdoor conversion panels (x2) 

  The rubber seals for the outdoor conversion panels (x2) 

  The PG9 cable glands made from stainless steel (x4) 

  The Fitting screws to generate sufficient seal pressure (x4) 

  The rubber plain washers as seals for the fitting screws (x4) 

  The rubber dummy plugs needed if a cable gland remains without cable (x3) 

 

To start expediting the connector change, please follow the below step-by-step 

instructions and draw your attention to the illustrations provided. Please note this refers 

to a conversion from indoor to outdoor; for the inverse conversion, please reverse the 

procedure’s steps 5-16.   

Summary of Contents for MultiSpot HQ5020

Page 1: ...Exclusive USA Distributor MultiSpot HQ5020...

Page 2: ......

Page 3: ...nd value Focused on you our goal is to ensure unparalleled support from the initial conversation to after sales service Our lighting experts and engineers will consult with you on ways to use our stan...

Page 4: ...020 High Power DMX Controlled LED light source For firmware 50 010 0088 00113 1 03 MS GII HQ5020 RevN Updated versions of this document may be available at WWW MULTIFORM LIGHTING COM RevB 08 2015 Orde...

Page 5: ...The Multispot GII is a high power DMX controlled LED light source for both indoor and outdoor applications which range from architectural illumination to stage lighting Available in various LED config...

Page 6: ...h greatest care Punches big forces and heavy vibration may damage this product mechanically Protection from eye injury 1 Warning Depending on the configuration of the device this device may reach or e...

Page 7: ...w at least about 0 15m 6 ins between this unit and other devices or a wall to allow for proper cooling 3 Take always care of sufficient air convection in the unit s environment to avoid overheating Ma...

Page 8: ...re parts Consequently take care of your dealer or maintenance company to be authorized by the manufacturer Health advice This unit produces and absorbs electromagnetic radiation The strength of radiat...

Page 9: ...r MULTISPOT GII HQ5020 has been factory fitted with connectors for both AC In Out and DMX In Out This configuration can be changed with comparatively little effort into an IP65 compliant outdoor versi...

Page 10: ...hat screws are fastened with the right torque during re assembly To expedite the connector change you will need Multiform s outdoor conversion kit for this unit which is available from your distributo...

Page 11: ...cover with the electronics assembly to face its inside Pull the cable stumbs far enough out to allow skinning of the leads inside the cables 12 Skin the separate leads of both the DMX and AC cables a...

Page 12: ...ed ers he im r 0 ed es he xx he is 0 ers ur will im ng ng an User Manual Multispot GII HQ5020 V2 00 08 2015 9...

Page 13: ...User Manual Multispot GII HQ5020 V2 00 08 2015 10 U V2 U...

Page 14: ...e the unit is properly matching the screws to avoid any damage to the screws This will require a 4mm HexInsert screw driver The screw driver has an in built torque measurement or you have other torque...

Page 15: ...Put the 5 lens panel screws back into place which hold the lens panel and tighten them with 0 50 0 55Nm torque 11 Check whether the front glass seal smoothly surrounds the front glass in proper positi...

Page 16: ...requirements of the used power supply if any Hanging Rigging ceiling mounted operation Risk of injury Overhead mounting requires extensive experience like calculating working load limits knowledge in...

Page 17: ...AC supply connections Risk of fire Safety risk The MULTISPOT GII HQ5020 LED requires an AC power source with sufficient power carriage and correct grounding to ensure safe operation The AC power sour...

Page 18: ...Button 5 Button 6 DISPLAY Sound to Light Indicator 7 DISPLAY 4 Digit Message Display Area 8 DISPLAY Indicator 9 DISPLAY Indicator 10 DISPLAY ARROW Indicators 11 DISPLAY DMX Signal Presence Indicator...

Page 19: ...mming level will remain as last set The same happens if the color preset is changed by the left right arrows in this case the dimming level mode is left immediately and the dimming level will remain a...

Page 20: ...SP8 yellow green turquoise blue candy red SP2 blue red SP9 Strobe red SP3 yellow red SP10 Strobe green SP4 candy lime SP11 Strobe blue SP5 candy blue SP12 Strobe white SP6 candy turquoise Use the left...

Page 21: ...defined as follow Pattern Steps Pattern Steps FP0 red green FP4 candy lime FP1 blue green FP5 candy blue FP2 blue pink red FP6 candy aqua turquoise FP3 yellow lime red FP7 red yellow green turquoise...

Page 22: ...ge can be mixed The attempt to use an external DMX controller as a master with all connected Multispot GII set to SLA mode will deliver unexpected and or confusing results use the GDMX setting instead...

Page 23: ...the number of consumed channels may change DO NOT try to leave the control mode channel scheme choice by pressing the left right arrow buttons this would change the control mode channel scheme to the...

Page 24: ...e UI will remain unlocked To unlock a locked unit press the left and the right arrow buttons simultaneously Auto Display off Use the left right arrows until the display shows ADIS Press any of the but...

Page 25: ...Secondary 25 degrees DMX Control 3 7 Channels IP Rating 20 indoor 65 outdoor Mains Input AC90 250V 50 60Hz Power supply type switch mode Power consumption 95W Fuse internal see service manual DMX conn...

Page 26: ......

Page 27: ......

Page 28: ...Apollo Design Technology Inc 260 497 9191 ApolloDesign net Copyright 2016 Apollo Design Technology Inc 2 16 MultiSpot HT5020...

Reviews: