7)  Remove the 5 standoffs that define the lens panel distance to the PCB by 

unscrewing them with left-turns. Keep these 5 standoffs stored together with 

the removed lens panel as every specific lens panel has its matching standoff 

length.  

8)  Insert the 5 standoffs that have been delivered with the new lens panel into the 

relative thread holes and fix them properly with right-turns.  

9)  Put the new lens panel into place by perpendicularly lowering it down on the 

LED panel. Make sure the LED panel is lowered in the right position, as 

lowering it in the wrong position may lead to collision between the lenses and 

the LEDs, which may damage the LEDs.   

10) Put the 5 lens panel screws back into place which hold the lens panel and 

tighten them with 0.50-0.55Nm torque. 

11) Check whether the front glass seal smoothly surrounds the front glass in 

proper position and put the front glass back into place, properly centering it on 

the mounting edge around the Lens/LED panel.  

12) Check whether the main seal is properly aligned and smoothly adapts to the 

groove around the lens/LED panel.  

13)  Carefully lower the front frame down on the main unit in the right position with 

aligned screw holes, avoiding any position change of the front glass with seal 

and the main seal during this procedure.   

14) Provide clamping of the main unit and the front frame by means of holding 

them together with both hands, and turn the unit around.  

15) Put the 8 screws back into place which connect the main unit with the front 

frame and tighten them with 3.0-3.3Nm

 

torque.  

16)  

 

 

 

User Manual: Multispot GII-HQ5020

    

                                       

 

V2.00 (08-2015)                                                                                                                                                

13

 

■ Getting started: choosing a location 

 

 

Risk of fire:

 The MULTISPOT-GII-HQ5020 LED has been designed for 

environmental temperatures of up to 40 degrees Celsius. For proper 

operation, the unit must be operated with unobstructed air convection to 

its outside metal case.  

 

Do not: 

  Operate the MULTISPOT-GII-HQ5020 LED in environments with more than 40 

degrees environmental temperature  

  Operate the MULTISPOT-GII-HQ5020 LED in any closed environment smaller 

than 10cbm, unless forced air convection is provided.  

 

■ 

Getting started: secure mounting

 

 

The MULTISPOT-GII-HQ5020 LED can be mounted in various ways: 

 

Floor standing operation 

 

  Turn the bracket to the lower side of the unit and fold out the second, inlaying 

bracket. 

  Place the unit in a secure position where it can neither be touched by anyone or 

could possibly become an objective for anyone to stumble.  

  Make sure to comply with cooling requirements of the used power supply if any.  

 

Hanging/Rigging, ceiling-mounted operation 

 

 

Risk of injury:

 Overhead mounting requires extensive experience, like 

calculating working load limits, knowledge installation materials, and 

periodic safety inspection of all installation material and the unit. If you 

lack such qualifications, do not attempt the installation yourself. 

Improper installation can result in body injury. Be sure to complete all 

rigging and installation procedures before applying power to the unit. 

 

  Leave the inner and outer bracket folded.  

  The unit should be installed out of reach of people and outside areas where 

persons may walk by or be seated.  

  Make sure that the installation area can hold a minimum point load of 10 times the 

device’s weight. 

  In fixed installations, fix the unit with self-locking screws/nuts to the mounting point.  

  When mounting the unit to truss be sure to secure an appropriately rated clamp to 

the hanging yoke using a M10 screw fitted through the center hole of the hanging 

yoke.  

  Where required, secure the installation with an appropriate safety cable. Always 

use a certified safety cable according to DIN56927 that can hold 12 times the 

Summary of Contents for MultiSpot HQ5020

Page 1: ...Exclusive USA Distributor MultiSpot HQ5020...

Page 2: ......

Page 3: ...nd value Focused on you our goal is to ensure unparalleled support from the initial conversation to after sales service Our lighting experts and engineers will consult with you on ways to use our stan...

Page 4: ...020 High Power DMX Controlled LED light source For firmware 50 010 0088 00113 1 03 MS GII HQ5020 RevN Updated versions of this document may be available at WWW MULTIFORM LIGHTING COM RevB 08 2015 Orde...

Page 5: ...The Multispot GII is a high power DMX controlled LED light source for both indoor and outdoor applications which range from architectural illumination to stage lighting Available in various LED config...

Page 6: ...h greatest care Punches big forces and heavy vibration may damage this product mechanically Protection from eye injury 1 Warning Depending on the configuration of the device this device may reach or e...

Page 7: ...w at least about 0 15m 6 ins between this unit and other devices or a wall to allow for proper cooling 3 Take always care of sufficient air convection in the unit s environment to avoid overheating Ma...

Page 8: ...re parts Consequently take care of your dealer or maintenance company to be authorized by the manufacturer Health advice This unit produces and absorbs electromagnetic radiation The strength of radiat...

Page 9: ...r MULTISPOT GII HQ5020 has been factory fitted with connectors for both AC In Out and DMX In Out This configuration can be changed with comparatively little effort into an IP65 compliant outdoor versi...

Page 10: ...hat screws are fastened with the right torque during re assembly To expedite the connector change you will need Multiform s outdoor conversion kit for this unit which is available from your distributo...

Page 11: ...cover with the electronics assembly to face its inside Pull the cable stumbs far enough out to allow skinning of the leads inside the cables 12 Skin the separate leads of both the DMX and AC cables a...

Page 12: ...ed ers he im r 0 ed es he xx he is 0 ers ur will im ng ng an User Manual Multispot GII HQ5020 V2 00 08 2015 9...

Page 13: ...User Manual Multispot GII HQ5020 V2 00 08 2015 10 U V2 U...

Page 14: ...e the unit is properly matching the screws to avoid any damage to the screws This will require a 4mm HexInsert screw driver The screw driver has an in built torque measurement or you have other torque...

Page 15: ...Put the 5 lens panel screws back into place which hold the lens panel and tighten them with 0 50 0 55Nm torque 11 Check whether the front glass seal smoothly surrounds the front glass in proper positi...

Page 16: ...requirements of the used power supply if any Hanging Rigging ceiling mounted operation Risk of injury Overhead mounting requires extensive experience like calculating working load limits knowledge in...

Page 17: ...AC supply connections Risk of fire Safety risk The MULTISPOT GII HQ5020 LED requires an AC power source with sufficient power carriage and correct grounding to ensure safe operation The AC power sour...

Page 18: ...Button 5 Button 6 DISPLAY Sound to Light Indicator 7 DISPLAY 4 Digit Message Display Area 8 DISPLAY Indicator 9 DISPLAY Indicator 10 DISPLAY ARROW Indicators 11 DISPLAY DMX Signal Presence Indicator...

Page 19: ...mming level will remain as last set The same happens if the color preset is changed by the left right arrows in this case the dimming level mode is left immediately and the dimming level will remain a...

Page 20: ...SP8 yellow green turquoise blue candy red SP2 blue red SP9 Strobe red SP3 yellow red SP10 Strobe green SP4 candy lime SP11 Strobe blue SP5 candy blue SP12 Strobe white SP6 candy turquoise Use the left...

Page 21: ...defined as follow Pattern Steps Pattern Steps FP0 red green FP4 candy lime FP1 blue green FP5 candy blue FP2 blue pink red FP6 candy aqua turquoise FP3 yellow lime red FP7 red yellow green turquoise...

Page 22: ...ge can be mixed The attempt to use an external DMX controller as a master with all connected Multispot GII set to SLA mode will deliver unexpected and or confusing results use the GDMX setting instead...

Page 23: ...the number of consumed channels may change DO NOT try to leave the control mode channel scheme choice by pressing the left right arrow buttons this would change the control mode channel scheme to the...

Page 24: ...e UI will remain unlocked To unlock a locked unit press the left and the right arrow buttons simultaneously Auto Display off Use the left right arrows until the display shows ADIS Press any of the but...

Page 25: ...Secondary 25 degrees DMX Control 3 7 Channels IP Rating 20 indoor 65 outdoor Mains Input AC90 250V 50 60Hz Power supply type switch mode Power consumption 95W Fuse internal see service manual DMX conn...

Page 26: ......

Page 27: ......

Page 28: ...Apollo Design Technology Inc 260 497 9191 ApolloDesign net Copyright 2016 Apollo Design Technology Inc 2 16 MultiSpot HT5020...