1. In the ‘IEC standards’ screen press the ‘IEC 4-13’ soft key.
2. Press the ‘Individual Harmonic’ soft key to display the Individual Harmonics test screen.
Individual Harmonics Setting
3. Press the ‘Edit’ soft key to set the required test selections for this test.
4. Move the cursor to highlight ‘Class =’ field, then press the [Enter] key to display the drop
down list.
5. Rotate the front panel knob to highlight ‘non-multiple of 3’ and press the [Enter] key to con-
firm.
64
The test time now run until completed. Total test time is determined by the Test Time setting.
The test time count down in seconds is visible in the upper part of the IEC 4-13 screen.
At the completion of the test, the ‘Stop’ soft key will revert to ‘Trigger’. To abort a test in pro-
gress, press the ‘Stop’ soft key during a test run.
Menu Operation
PROFESSIONAL INNOVATIVE BRANDING SERVICE
The test time now run until completed. Total test time is determined by the Class and Level
settings.
The test time count down in seconds is visible in the upper part of the IEC 4-13 screen.
At the completion of the test, the ‘Stop’ soft key will revert to ‘Trigger’. To abort a test in pro-
gress, press the ‘Stop’ soft key during a test run.
65
6. Move the cursor to highlight ‘Level =’ field, then press the [Enter] key to display the drop
down List.
7. Rotate the front panel knob to highlight ‘Class 2’ and press the [Enter] key to confirm.
8. Press the ‘Save’ soft key to store the test setting in non-volatile memory.
9. Press the [ESC] key to return to the previous screen then press the ‘Load’ soft key to load
the settings.
10. Press the ‘Trigger’ soft key to execute the file. Once pressed, it changes to ‘Stop’.
Menu Operation
PROFESSIONAL INNOVATIVE BRANDING SERVICE