Appendix B: Accessories
● Installation flanges
30
3DLevelScanner Operating Instructions © 2013 APM all rights reserved
Flange type DN250
Flange thickness: 6.5mm (0.25").
Flange preparation and installation guidelines
The transducer case must fit in the hole in the vessel. If this cannot be reached, use
alternative solutions such as neck extension or lowering the scanner inside the vessel.
The widest part of the scanner is the transducers case: 193.3mm (7.61")
Insert the flange onto the neck tube
Tighten the nut to the neck thread using an 18" adjustable wrench
Note: The diameter of the hole in the center of the flange center is 52mm (2.1")