3DLevelScanner Operating Instructions © 2013 APM all rights reserved
23
Appendix A: Onboard Configuration
Output Settings
This function defines the scanner Polling Address, and further to Measured Parameter
settings. Navigate down at the Main Menu screen using the key, select the
Output
Settings
option and press to enter the Output settings menu.
The first screen of
Output Settings
allows setting
the scanner polling address.
Set the proper
Polling Address
using the
/
keys, and press to proceed.
Exiting this menu with the
automatically
switches to the main
menu.
When needed, it is possible to enter the scanner
into simulation mode, there are four options:
Simulation Off, Level Simulation, Volume
Simulation and Current Simulation. Navigation is
done with the / keys, press to proceed.
/ keys, and press to
proceed.
When setting the level simulation, the scanner will
calculate the set level between the Full and
Empty calibration levels. Set the level using the
/ keys, and press to proceed.
Press the button to apply selection and to
display the calculated mA value.
If the value exceeds the difference between the
full and empty calibration levels, the scanner will
alert that the max value is XXm.
Volume simulation allows setting the volume in
percentage between 0 to 100%. Set the volume
using the / keys, and press to proceed.
If the value exceeds 100%, the scanner will alert
that the max value is 100%.
Polling Address
00
Simulation
→sim. Off.
sim. Level
sim. Volume
Simulation value
00.00m
Simulation value
000.00%