5 Acceptance  and transportation

 

EN     Floor  grinding machine DSM 530S  / DSM 650S  / DSM 800S

 

 
 
 

 
 
 

 

6 Troubleshooting  

 

 

  

Only  suitably knowledgeable,  qualified profes- 

sional technicians may  perform repairs on  the

 

machine.

 

 

Malfunction

 

Cause

 

Rectification

 

Machine will not 
start.

 

The voltage supply has not 
been properly connected.

 

Join the connecting cable (extension cable) with a proper 
power socket and plug the connecting cable’s plug into 
the power plug [4, Fig. A].

 

Connecting cable is defec- 
tive.

 

Replace connecting cable.

 

Safety switch is defective.

 

Replace safety switch.

 

The safety cap

 

[17,  Fig. B/D] is not  pro-

 

perly engaged.

 

If necessary, press the safety cap on  the safety switch until 

it snaps in.

 

EMERGENCY  STOP  but- 
ton  is pressed.

 

1.      

Turn 

FWD/0/REV 

rotary switch to 

0

.

 

2.      

Determine the cause for the emergency stop  and 

rectify if  necessary.

 

3.      

Unlock the EMERGENCY  STOP  button  afterwards.

 

When using  an 
extraction, the 
suction housing 
sucks itself to 
the floor.

 

There is not  adequate 
clearance between the 
dust cover and the surface 
to be ground.

 

Correct the clearance between the dust cover and the 

surface to be ground  (     Chapter 3.1  - page 17).

 

Grinding 
pattern is 
uneven.

 

Tools are loose.

 

Fasten tools.

 

Tools are damaged 
or worn.

 

Replace tools.

 

Machine 

shuts down  by 
itself.

 

Machine is overloaded. 
The drive overload protec- 
tion (MOP)  has triggered.

 

1.      

Press RESET  button  [15,  Fig. B].

 

2.      

Put  the machine into operation

 

(     Chapter 3.1  - page 17).

 

3.      

If necessary, reduce the speed  with the 

SPEED 

regula- 

tor.

 

Connecting cable (exten- 
sion  cable) is too  long.

 

The minimum diameter and the maximum length of the 
con- nection line (extension cable)  Chapter 7

 

Faulty power supply.

 

Check the connecting cable (extension cable) and replace 
if necessary.

 

Use a different power socket if  necessary.

 

The motor  is ro- 
tating but  the 
grinding plate is 
not  turning 
under load.

 

The main drive belt is sli- 
ding out.

 

To tension the main drive belt:

 

1.      

Switch the machine off

 

(     Chapter 3.4  - page 18).

 

2.      

Tilt machine

 

(     Chapter 4.2  - page 19).

 

3.      

Unscrew the screw [41].

 

4.      

Tighten the clamping screw 1½  rotations clockwise with 

the [42] spanner [40] (     arrow).

 

5.      

Retighten the screw  [41] with the spanner (turning lock,

 

  Fig. N).

 

6.      

Place the machine in operation (     Chapter 3.1  - page

 

17).

 

7.      

Check whether the grinding plate turns under load.

 

8.      

If the belt tension is not  yet  sufficient, repeat steps 

1 through 7.

 

Summary of Contents for DSM 530S

Page 1: ...grinding machine DSM 530S DSM 650S DSM 800S Translation of the original operating manual 14 FR Ponceuse de sol DSM 530S DSM 650S DSM 800S Traduction du manuel d utilisation original 24 NL Vloerslijpma...

Page 2: ...2 3 8 7 Fig A 11 DSM 530S DSM 650S 24 2 9 3 1 10 4 25 Fig C 12 5 6 8 17 11 20 9 Fig D Fig A DSM 800S 1 2 12 4 3 5 7 7 11 8 21 22 Fig E Fig F 1 3 9 Fig B 13 23 2 14 19 15 18 16 17...

Page 3: ...2 3 3 39 7 Fig G DSM 800S Fig L Fig M DSM 530S DSM 650S 36 Fig H 38 Fig I 26 27 28 31 29 32 Fig M DSM 800S 30 36 Fig J 37 Fig K 34 35 50 max 16 42 40 41 Fig N...

Page 4: ...ep com au URL www AllPrep com au Document DSM530S 650S 800S Publishing date 15 11 2012 Schwamborn Ger tebau GmbH reserves all rights Any reproduction use or distribution of this original operating man...

Page 5: ...ie with Schwamborn Ger tebau GmbH No part of this documentation may be reproduced used or distributed in any form without the written permission of Schwamborn Ger tebau GmbH Liability or warranty is e...

Page 6: ...e during operation or maintenance work Risk of injury if safety devices have been removed or are non functional The safety fixtures must be checked for completeness and function before starting up The...

Page 7: ...paid to dama ged or loose components wearing and fil ling levels Always use ETX diamond tools or abrasive bonding for the surface to be machined e g some surfaces have to be ground wet 1 Disconnect t...

Page 8: ...be machined 5 Select the rotation direction with the FWD 0 REV rotary switch 18 Fig B FWD forward The gears turn anticlockwise the ETX lo cating plates turn clockwise REV backwards The gears turn clo...

Page 9: ...clamping nuts 21 Fig E anticlockwise until thelok king disks 22 Fig E are no longer enga ged 5 Adjust the guide bar to the upper stretched position Fig F and tighten the clamping nuts clockwise so tha...

Page 10: ...L and tighten the clamping nuts clockwise so that the locking disks engage or Restart the machine Chapter 3 1 page 17 5 Acceptance and transportation Follow the safety instructions in Chapter 2 5 1 Ma...

Page 11: ...machine can be transported on palettes to pro tect the machine from damage The machine can be relocated over shorter distances in the tipped position with the transport wheels 1 Decommission the machi...

Page 12: ...rance between the dust cover and the surface to be ground Chapter 3 1 page 17 Grinding pattern is uneven Tools are loose Fasten tools Tools are damaged or worn Replace tools Machine shuts down by itse...

Page 13: ...rating IP 23 IP 23 IP 23 Dust extraction 76 mm 76 mm 76 mm Water connection Tank 15 litres Tank 15 litres Gardena system Dimensions L x W x H Operation app Transport app 1600 x 580 x 1260 mm 890 x 58...

Page 14: ...ective 2006 95 EC Low Voltage The following harmonised standards apply EN 292 1 EN 292 2 EN 13857 Safety of Machinery EN 60204 1 Electrical Equipment of Machines EN 50081 2 EN 50082 2 EN 61000 6 2 Ele...

Reviews: