①
P
lace the ion bar in the working area where static electricity is
to be
eliminated. The AP-AB1602A ion bar should be about 100~ 300mm
away from the surface of discharged object and
the installation angle should be perpendicular to the surface of the charged body.
②
The surface of ion bar is not allowed to be covered by other objects.
③
Two AP-AB1602A ion bars should be installed side by side with an interval of more than 300mm and should be staggered by more than 300mm
if installed face-to-face.
④
More than 200mm away from obstacles such as walls.
⑤
I
on bar should be at least
3
0mm away from the metal conductor and metal
g
roundin
g
body around the electrode. And the bar body must be
reliably connected to the A
C
e
q
ui
p
ment
g
roundin
g
wire and the
g
roundin
g
resistance should be less than 1 ohms.
Warning
It is necessary to ensure that the air is dry and clean when using a compressed air source to enter the ion bar to avoid the moisture,
grease, and dust in the air source from contaminating electrode needles causing high-voltage insulation failure which affects normal use.
Installation distance
Discharged object
≥ 300mm
≥ 300mm
Step of use
Installation position
Galvanized Hexagon Bolt
1LML05000
M5
Hex nuts
1SL00520X
M5*20
Packing accessories
Products Use
Step of use/Installation position/Packing accessories
①
Select the best static discharge position and install the bar body and the supporting
power
supply
firmly.
②
Insert the high-voltage plug of the bar body into the high-voltage output connecting
seat of the
supporting
high-voltage power supply.
③
Connect the grounding terminal of the bar body to the grounding stud of the high
voltage power supply.
④
Connect the air source connector on bar body(air source type) to the air source
generating device and turn on the air source switch.
⑤
Turn on the power switch and indicator light on shows the power work. Adjust
the proper air source pressure to generate positive and negative ions at the
electrode needles to neutralize the surface static electricity of the object.
WALL
WALL
WALL
WALL
Metal conductor
Metal conductor
Metal conductor
Metal conductor
Part name
Picture
Part No.
Specification