background image

Special conditions for the safe use of products

The suffix “X” of the explosion-proof certificate No. indicates that the product has special conditions for safe use. The specific contents are as

follows:

The product cannot be used in places where conductive objects may adhere to the static elimination electrodes 

(Static eliminating

electrodes may not work when attached to conductive materials such as carbon and metal foil)

.

It should be more than 20mm away from the static elimination object when the static elimination electrode is installed.

The distance between the static elimination electrode and the mechanical frame should be more than 10mm.

Keep the static-eliminating electrode clean and it is strictly forbidden to dry-clean the static-eliminating electrode support.

The power supply unit which does not have an explosion-proof structure must be installed in a non-hazardous location.

The maximum length of high-voltage cable is 8m.

It is strictly forbidden to open the cover.

It is strictly forbidden to rub the surface of the product shell to prevent the risk of static electricity ignition.

Precautions for product use

The environment range of products allowed to use: 

Temperature

:(

 +50

)℃

Relative humidity:

35% 

 75%

Altitude

not more than 1000m

The product is equipped with a grounding terminal, users should ground it reliably during installation and use.

The principle of “No opening with power on” must be observed during on-site use and maintenance of the product.

Users are not allowed to replace parts or components of this product by themselves and should work with the product

 

manufacturer to solve the faults in operation to prevent damage.

The electrical parameters of the eliminator are as follows:

Discharge device

Static elimination electrode

Power supply unit

Model

Voltage(V) Frequency (Hz) Needle binding capacity(pF/ group) Primary voltage(V)

Secondary voltage (V)

Frequency (Hz) Capacity (VA)

Insulation class

AP-AB1602A

≤ 7000

50

3.5

100

≤ 7000

50

25

E

110
220

Warning

Warning

The installation, use and maintenance of the product should also abide by the product manual and the requirements of the following related 
standards and specifications: 

GB 3836.13–2013 Explosive environment Part 13: Repair, overhaul, repair and modification of equipment
GB 3836.15–2000 Electrical equipment for explosive gas atmospheres Part 15: Electrical installations in hazardous locations (except coal mines)

 

GB 3836.16–2006 Electrical equipment for explosive gas atmospheres Part 16: Inspection and maintenance of 

electrical devices

 (except coal mines)

 

GB 50257-2014 Explosion and fire hazard environment of electrical equipment installation engineering construction and acceptance specification for electrical equipment
GB 3836.18–2010 Explosive environment Part 18: Intrinsically safe system 

Read the operating instruction carefully before installing and using the device.

The whole equipment must be reliably connected to the ground of the AC equipment and the grounding resistance is less than 1 ohms 

during use; Otherwise, it is easy to cause abnormal or even damage of ion bar.

It is strictly forbidden to disassemble products without authorization. Internal maintenance and repair must be carried out by professional 

personnel.

The product is strictly prohibited to touch liquid during use, otherwise there will be abnormal, resulting in electric shock or fire.

Power must be turned off during inspecting or replacing the product, otherwise it may cause electric shock or fire.

The product is specially designed for removing static electricity and is strictly prohibited for other purposes. Any abnormal use may 

cause machine failure, electric shock, fire and other hidden dangers.

It is strictly forbidden to touch the electrode needles when power is on, otherwise it is easy to cause fault and electric shock accident.

Discharge needle is a sharp metal object, please use it with care.

Please check the specifications of the power supply before powering on the product. Any power supply that does not meet the 

specifications may cause damage or even failure to the product.

Check the power cord regularly. If it is damaged, replace it immediately; otherwise, leakage and abnormal operation may occur.

Summary of Contents for AP-AB1602A

Page 1: ...Explosion proof Ion Bar Series AP AB1602A Explosion proof Ion Bar Series AP TR Shanghai Anping Static Technology Co Ltd AP T...

Page 2: ...and other industries with flammable working conditions Effectively solve the problems caused by static electricity Static Removal Prevent uneven scattering Control ink splashing Prevent adhesion of ob...

Page 3: ...nd explosive working places corresponding to B or lower level with this safe explosion proof function Can be used safely in flammable and explosive environments Explosion proof certificate No GYB21 33...

Page 4: ...150 0 150 600 550 500 450 400 350 300 33 6 37 2 40 7 44 3 47 8 51 4 55 0 58 5 62 1 65 6 69 2 Z mm Y mm 150 150 Discharge ability Working way High Efficiency Static Removal Keep a clean production env...

Page 5: ...182 1 500 150 0 2 6 783 6 225 36 7 28 85 94 4 0 2 785 2 487 3 4 52 35 101 3 150 5 16 4 349 31 3 37 15 105 6 150 0 4 3 295 3 46 28 1 69 15 110 2 0 1 683 1 408 13 9 66 4 118 9 150 3 213 2 911 1 7 56 1...

Page 6: ...able to left or right and can be easily installed in different environments CE certification It can effectively avoid external electromagnetic interference affecting the normal operation of the ion ba...

Page 7: ...0mm 600mm Installation distance 100 600mm Air pressure 0 6MPa Compressed air connector 8 G1 8 white Ion balance 50V Discharge speed 2 5S Test data may vary with test conditions Working temperature 0 5...

Page 8: ...bolt M5 20 Shielded high voltage wire Air source connector with throttle Product size Product details Sliding mounting bolt M5 20 Discharge electrode Stomata Ground terminal High voltage plug Shielde...

Page 9: ...om contaminating electrode needles causing high voltage insulation failure which affects normal use Installation distance Discharged object 300mm 300mm Step of use Installation position Galvanized Hex...

Page 10: ...nstallation use and maintenance of the product should also abide by the product manual and the requirements of the following related standards and specifications GB 3836 13 2013 Explosive environment...

Page 11: ...d and maintained regularly with electrostatic brush dust free cotton swab dust free cloth dipped in anhydrous alcohol according to the use environment and the required electrostatic protection require...

Page 12: ...g analysis and elimination solution provider Speciality Creates Value AP T Shanghai Anping Static Technology Co Ltd Tel 86 21 64517676 Fax 86 21 64517673 Postcode 200233 Website www ap static com Addr...

Reviews: