Product model
:
AP-AB1602A
Power
:
7KV 1 capacitor
Test instrument
:
TREK158
Ion bar length
:
100cm
Test distance
(
mm
)
Air pressure
(
MPa
)
1*
Discharge performance
Vertical Horizontal
Positive discharge
time (S)
Negative discharge
time (S)
MIN
Balance voltage
AVE(
V
)
MAX
300
-150
0.2
7.461
6.049
-59.4
35.35
130.1
0
1.525
1.397
-56.7
40.7
138.1
150
4.127
4.773
-65.8
40.3
146.4
-150
0.4
4.697
5.487
-34.6
54.6
143.8
0
0.888
0.778
-20.6
66.1
152.8
150
6.225
4.253
-98.9
33.65
166.2
-150
0.6
4.439
3.527
-21.4
69.3
160
0
0.706
0.571
-10
77.5
165
150
7.514
4.231
-78.8
51.65
182.1
500
-150
0.2
6.783
6.225
-36.7
28.85
94.4
0
2.785
2.487
3.4
52.35
101.3
150
5.16
4.349
-31.3
37.15
105.6
-150
0.4
3.295
3.46
28.1
69.15
110.2
0
1.683
1.408
13.9
66.4
118.9
150
3.213
2.911
-1.7
56.1
113.9
-150
0.6
3.164
2.785
29.1
77.3
125.5
0
1.506
0.98
44.7
92.05
139.4
150
3.646
2.324
24
78.55
133.1
600
-150
0.2
7.988
6.336
-14.7
35.35
85.4
0
3.128
2.794
-4.2
44.95
94.1
150
6.431
6.559
6.6
47.75
88.9
-150
0.4
4.254
3.215
11.4
56.35
101.3
0
2.178
1.814
24
65.45
106.9
150
3.498
2.733
0.7
51.8
102.9
-150
0.6
2.886
2.468
37.6
79.35
121.1
0
1.931
1.285
58.6
96
133.4
150
3.191
2.504
33.7
80.15
126.6
with air source
AP-AB1602A
150mm
150mm
300mm
0.7s
7.5s
4.4s
500mm
1.5s
6.5s
3.1s
600mm
1.9s
3.1s
2.8s
150mm*150mm plate tester
Other test data