Ion bar adopts power frequency AC high voltage and
acts on the dedicated emitter electrode through
impedance coupling devices to ionize air molecules
to generate positive and negative high voltage ions
and transport them to the surface of the object to be
eliminated to neutralize positive and negative
electrostatic charges to achieve efficient and reliable
static elimination.
AC
High voltage power supply
Power frequency AC
T
Positive voltage working time
Negative voltage working time
+HV
(Positive high pressure)
-HV
(Negative high pressure)
-150
0
150
600
550
500
450
400
350
300
0.9
1.4
2.0
2.5
3.0
3.6
4.1
4.6
5.2
5.7
6.2
-150
0
150
600
550
500
450
400
350
300
33.6
37.2
40.7
44.3
47.8
51.4
55.0
58.5
62.1
65.6
69.2
Z(mm)
Y(mm)
-150
150
Discharge ability
Working way
High Efficiency Static Removal
Keep a clean production environment and stay
away from static electricity
Test Height Z (mm)
Test Height Z (mm)
Test Width Y (mm)
Test Width Y (mm)
Discharge
Time
(
s
)
Ion Balance(V)
Discharge time
distribution
diagram
of AP-AB1602A
with 1000mm
b
ar
l
ength at 0.4MPa air pressure
Ion balance voltage distribution diagram of AP-AB
160
2
A
with
1000mm
b
ar
le
ngth at 0.4MPa air pressure
Test bearing chart
Trek 150*150mm
plate tester
Vertical test distance
Horizontal test distance
front and back
Test standard
:
ANSI/ESD.STM3.1
,
SJ/T 11446—2013
Test instrument
:
Trek charge plate tester
Test voltage
:
±1000V → ±100V attenuation
Test environment
:
humidity 50±5%
;
temperature 23±3
℃