OPERATING GUIDELINES
9. Deactivate the Hot Air Gun Activation button first in order to activate
the auto-cooling process. The system will start to blow air (at room
temperature) at a fast rate to reduce heat from the hot air gun and
bring down the temperature to a reasonable safe level of 90°C. During
this time, the prefix of the display for hot air gun temperature will also
change from “H” to “C” while temperature is gradually decreasing.
Likewise, the air pressure level is at its highest reading as indicated
from the display panel. Once the temperature drops to approximately
90°C the system will halt and display “OFF” on the panel. It is now safe
to switch off the main power switch.
10. Turn OFF the main power switch.
11. Unplug the device from the main power source.
D. SOLDERING IRON
1. Connect the Soldering Iron connection assembly to the 6-pin receptacle
located at the front of the control panel (“8” from the CONTROL PANEL
GUIDE).
2. Follow the initial procedures (“A. INITIAL PROCEDURES”).
3. Activate the “SOLDER IRON” Activation switch (“11” from control
panel). This will automatically start to increase the temperature of the
soldering iron to 350°C (default).
4. Adjust the soldering iron temperature using the SOLDERING IRON
ADJUSTMENT buttons (“6” from the control panel).
5. Start using the soldering iron as soon as desired temperature is
reached.
6. Deactivate the SOLDER IRON activation switch.
7. Allow sufficient time for the soldering iron to cool down before keeping
in a safe storage.