15
OPERATING GUIDELINES
1. Start using the soldering iron as soon as desired temperature is
reached.
2. When the task is finished, deactivate the SMOKE ABSORBER switch.
3. Deactivate the SOLDER IRON activation switch.
4. Allow sufficient time for the soldering iron to cool down before
keeping in a safe storage.
E. DESOLDERING GUN
1. Connect the De-soldering gun connection assembly to the 6-pin
receptacle located at the front of the control panel (“9” from the
CONTROL PANEL GUIDE).
2. Follow the initial procedures (“A. INITIAL PROCEDURES”).
3. Connect the vacuum tube to the Smoke Absorber Terminal or
Vacuum Cap (“7” from the control panel).
4. Activate the “DESOLDER GUN” Activation switch (“12” from control
panel). This will automatically start to increase the temperature of
the desoldering gun to 350°C (default).
5. Adjust the desoldering gun temp. using the DESOLDER
TEMPERATURE ADJUSTMENT buttons (“5” from the control panel).
6. Allow the desoldering gun's tip and its barrel to heat up. Tip
temperature can be reached within 5-6 minutes and its barrel would
obtain optimum temperature 5-9 minutes after the tip temperature
has been reached. If upon initial use solder gets stuck at the end of
the barrel, clean the barrel and wait a few more minutes for the
barrel to heat up.
7. Check the tip temperature with an external temperature sensor,
adjust temperature settings higher or lower for the right
temperature. Or recalibrate at the desired temperature level
8. Ensure that all the solder is melted before triggering the pump.
(Partially melted solder will still be sucked up however it would clog
the barrel).
Summary of Contents for INT 2703A+