background image

16

 

MAINTENANCE 

IMPORTANT: 

Unless  otherwise  directed,  carry  out  these  procedures 

with the power switched OFF and the power cord UNPLUGGED.

 

CARBON FILTER 

 

A  filter  device  is  installed  at  the  vacuum  outlet  (see

  D2 

of 

panel  controls    reference  page)  .  The  filter  pad  should  be 
cleaned  and  replaced  regularly,  depending on the  frequency 
of use.

 

REPLACING THE HEATING ELEMENT 

1.  Loosen  the  3  screws  that  secure  the  hot  air  gun  handle.  The 

heating element is located in the middle part of the hot air gun. 

2.  Slide off the plastic tube. 

3.  Disconnect the ground wire sleeve. 

4.  The Quartz glass and heat insulation are installed inside the pipe. 

Loosen the cable and remove the heating element. 

5.  Insert  the  new  heating  element  and  reconnect  the  terminal.  Be 

careful not to rub or touch together the heating element wire. 

6.  Reconnect the ground wire after replacing the heating element. 

7.  Re­assemble the handle.

 

NOTE: 

The  life  expectancy  of  a  heating  element  is  1  year  under 

normal operating conditions.

 

K1 —  filter drawer 
K2 — active carbon filter pads (30181X) 
K3 — smoke absorption nozzle 

5

 

PRODUCT SPECIFICATION

 

Power Input : 

available in 110V & 220V 

Main Station Dimensions: 

188(w) x 126(h) x 250(d) mm 

Weight: 

5.25Kg 

SOLDERING IRON

 

Power Consumption: 

70W 

Temperature Range: 

200°C ­ 480°C 

Heating Element with Tip: 

Ceramic Heater 

Output Voltage: 

24V 

Tip to Ground Resistance: 

Below 2 Ω 

Tip to Ground Potential: 

Below 2mV 

HOT AIR

 

Power Consumption: 

550W 

Temperature Range: 

100°C ­ 480°C 

Heating Element 

Metal Heating Core 

Nozzle to Ground Resistance: 

Below 2 Ω 

Pump/Motor Type: 

Diaphragm Pump 

Air Capacity: 

23 l /min (max) 

SMOKE ABSORBER

 

Vacuum Pressure: 

600mm Hg

Summary of Contents for 968A+

Page 1: ...rsonnel or damage to items in the workplace may result if not carefully used Please read the contents on how to use the equipment and observe the following in order to maximize usage After opening the...

Page 2: ...rflow level is noticeably weaker SOLUTION Try to press the Reset button on the panel and let the device re detect the proper operating frequency Note that resetting the device will also reset all prev...

Page 3: ...ading is not increasing or decreasing based on desired level set temperature The panel will then display a blinking OFF on display panels C2 and C3 afterwards SOLUTION The heating element may be broke...

Page 4: ...s Easily adjust temperature offset with a few simple adjustments Intelligent error reporting mechanism Detects and informs the personnel for problems with the sensor and heating element Auto cooling f...

Page 5: ...nt and reconnect the terminal Be careful not to rub or touch together the heating element wire 6 Reconnect the ground wire after replacing the heating element 7 Re assemble the handle NOTE The life ex...

Page 6: ...te temperature when soldering 2 Cleaning Always clean the soldering tip before using Remove any residual solder or flux that are still adhering to the tip Use a clean and moist cleaning sponge to remo...

Page 7: ...error SOLDERING IRON SMOKE ABSORBER 1 Turn on Soldering Iron function and set to desired working temperature Wait for soldering iron to reach set temperature 2 Turn on the Smoke Absorber function swi...

Page 8: ...ration value into the memory 3 Set soldering iron to desired working temperature 4 Wait a few minutes for the temperature to stabilize before checking the temperature difference with an external calib...

Page 9: ...st the calibration number of the soldering iron Turn SMD and Smoke absorber function switch off Turn Soldering iron function switch on Press and hold the hot air temperature increase button A6 9 SMD R...

Page 10: ...A2 will show the current set temperature based on the knob position 11 OPERATING GUIDELINES 5 After a few seconds the digital display A2 will switch to showing the actual temperature You may start sol...

Reviews: