16
MAINTENANCE
IMPORTANT:
Unless otherwise directed, carry out these procedures
with the power switched OFF and the power cord UNPLUGGED.
CARBON FILTER
●
A filter device is installed at the vacuum outlet (see
D2
of
panel controls reference page) . The filter pad should be
cleaned and replaced regularly, depending on the frequency
of use.
REPLACING THE HEATING ELEMENT
1. Loosen the 3 screws that secure the hot air gun handle. The
heating element is located in the middle part of the hot air gun.
2. Slide off the plastic tube.
3. Disconnect the ground wire sleeve.
4. The Quartz glass and heat insulation are installed inside the pipe.
Loosen the cable and remove the heating element.
5. Insert the new heating element and reconnect the terminal. Be
careful not to rub or touch together the heating element wire.
6. Reconnect the ground wire after replacing the heating element.
7. Reassemble the handle.
NOTE:
The life expectancy of a heating element is 1 year under
normal operating conditions.
K1 — filter drawer
K2 — active carbon filter pads (30181X)
K3 — smoke absorption nozzle
5
PRODUCT SPECIFICATION
Power Input :
available in 110V & 220V
Main Station Dimensions:
188(w) x 126(h) x 250(d) mm
Weight:
5.25Kg
SOLDERING IRON
Power Consumption:
70W
Temperature Range:
200°C 480°C
Heating Element with Tip:
Ceramic Heater
Output Voltage:
24V
Tip to Ground Resistance:
Below 2 Ω
Tip to Ground Potential:
Below 2mV
HOT AIR
Power Consumption:
550W
Temperature Range:
100°C 480°C
Heating Element
Metal Heating Core
Nozzle to Ground Resistance:
Below 2 Ω
Pump/Motor Type:
Diaphragm Pump
Air Capacity:
23 l /min (max)
SMOKE ABSORBER
Vacuum Pressure:
600mm Hg