background image

10

 

OPERATING GUIDELINES 

5.  Set the desired air temperature using buttons A6 and A7. 

6.  You  may  start  reworking  as  soon  as  the  desired  temperature  is 

reached. Refer to display panel C3 to verify. 

7.  When   reworking   is   completed,   turn   off   the

  “SMD   Rework” 

function  switch.  The  auto­cooling  functionality  will  commence  if 

the system detects a temperature higher than 95°C. It will blow at 

full speed to accelerate the cooling down of the hot air gun.  The 

auto­cooling  functionality  will  stop  when  the  temperature  of  the 

hot  air  gun  reaches  about  95°C  or  below,  as  shown  from  the 

actual temperature display panel, C3. The system will then switch 

off and display an “OFF” message from user­defined temperature 

display panel, C2.

 

NOTE: 

Make sure the smoke absorption functionality is switched OFF when 

using the equipment for SMD Rework.

 

SOLDERING IRON 

1.  With the unit plugged to the main power source and main power 

switch   in   the   ON   position,   ensure   that   the   soldering   iron   is 

properly connected to the receptacle, D1. 

2.  The soldering iron display  A3 will  show the word “OFF” indicating 

the soldering iron function is turn off. 

3.  To use the soldering iron turn ON the

 “Soldering Iron” 

function 

switch, B1. 

4.  The  soldering  iron  display  A3  will  briefly  show  the  current  set 

temperature then switch to displaying the actual temperature. 

5.  When   we   use   the   adjustment   knob,   A3,   to   set   the   desired 

soldering   temperature.     The   digital   display   A2   will   show   the 

current set temperature based on the knob position. 

11

 

OPERATING GUIDELINES 

5.  After  a  few  seconds  the  digital  display  A2  will switch to  showing 

the actual temperature. You may start soldering when the desired 

temperature has been reached.  The small dot located at the end 

of  the  number  displayed  in  A2  signifies  the  heater  regulation. 

When  the    small  dot  starts  blinking  on  and  off  the  system  has 

reached the desired set temperature. 

6.  After usage turn off the soldering iron function switch. 

7.  If  the  soldering  iron  tip  is   still   higher  than  100   degrees,   the 

soldering  iron  display  will  show  the  word  “Hot”  indicating  the 

soldering iron is still hot to caution users. 

8.  When   the   soldering   iron   tip’s   temperature   has   fallen   to 

manageable level the display will show the work “OFF” 

9.  Switch ON  the

 “Smoke Absorber” 

power switch, B2, to activate 

the smoke absorption functionality.

 

NOTE: 

Turn the  “Smoke Absorber” ON only after the soldering iron reached 

the  desired  (set)  temperature.  This  is  to  avoid  affecting  the  temperature 
increase of the soldering iron in terms of heating time.

 

SOLDERING IRON SLEEP TIMER 

1.  The  soldering  iron  has  a  sleep  feature  that  allows  the  soldering 

iron   to   go   into   sleep  mode   depending   on   user  programmed 

duration. 

2.  To access and enable the sleep feature of the soldering iron: 

 

Turn Soldering iron, SMD and Smoke absorber function switch off. 

 

Press and hold the hot air temperature increase button A6. 

 

The  soldering  iron  display  A2  will  turn  to  “t##”  ,  indicating  it  is 

now on sleep timer adjustment mode. 

 

Turn the soldering iron   adjustment knob to select desired sleep 

time in minutes.

Summary of Contents for 968A+

Page 1: ...rsonnel or damage to items in the workplace may result if not carefully used Please read the contents on how to use the equipment and observe the following in order to maximize usage After opening the...

Page 2: ...rflow level is noticeably weaker SOLUTION Try to press the Reset button on the panel and let the device re detect the proper operating frequency Note that resetting the device will also reset all prev...

Page 3: ...ading is not increasing or decreasing based on desired level set temperature The panel will then display a blinking OFF on display panels C2 and C3 afterwards SOLUTION The heating element may be broke...

Page 4: ...s Easily adjust temperature offset with a few simple adjustments Intelligent error reporting mechanism Detects and informs the personnel for problems with the sensor and heating element Auto cooling f...

Page 5: ...nt and reconnect the terminal Be careful not to rub or touch together the heating element wire 6 Reconnect the ground wire after replacing the heating element 7 Re assemble the handle NOTE The life ex...

Page 6: ...te temperature when soldering 2 Cleaning Always clean the soldering tip before using Remove any residual solder or flux that are still adhering to the tip Use a clean and moist cleaning sponge to remo...

Page 7: ...error SOLDERING IRON SMOKE ABSORBER 1 Turn on Soldering Iron function and set to desired working temperature Wait for soldering iron to reach set temperature 2 Turn on the Smoke Absorber function swi...

Page 8: ...ration value into the memory 3 Set soldering iron to desired working temperature 4 Wait a few minutes for the temperature to stabilize before checking the temperature difference with an external calib...

Page 9: ...st the calibration number of the soldering iron Turn SMD and Smoke absorber function switch off Turn Soldering iron function switch on Press and hold the hot air temperature increase button A6 9 SMD R...

Page 10: ...A2 will show the current set temperature based on the knob position 11 OPERATING GUIDELINES 5 After a few seconds the digital display A2 will switch to showing the actual temperature You may start sol...

Reviews: