-BL296*B16F*4A20 10/11-

[Specifications]

[Outside dimensions]

■ 

The dimensions are common to all models.

(200)

(57)

14.6

37.1

91

(21)

38.5

19.25

84.5

3.25

2-

Φ

3.5

24V

NC

0V

OUT

OUT

0

OUT

8

R/W

LINK ALM

0

1
2
3
4

5
6

7

8

9

10
11
12

13
14
15

24V

NC

0V

OUT

Unit: mm

*The figure is an example of BL296PB-16F-4A-20.

UL style 20276
4 wires × No.23AWG Ø 4.6 Gray

BL296PB-

16F-4A-20

68.7

15.7

6.6

4.5

Detecting transmission signal level reduction
Defecting I/O voltage reduction

BL296SB-16F-4A-20

BL296SB-16FS-4A-20

BL296XB-16F-4A-20

BL296XB-16FS-4A-20

NPN  

Input 16 point

PNP 

Input 16 point

NPN 

Input 8 point, Output 8 point

PNP 

Input 8 point, Output 8 point

BL296PB-16F-4A-20

BL296PB-16FS-4A-20

NPN 

Output 16 point

PNP 

Output 16 point

Individual Specifications

General Specifications

Transmission Specifications

Number of 

occupied 

data items

Response time

*

3

BL296SB-16F-4A-20 

60g

BL296XB-16F-4A-20 

60g

BL296PB-16F-4A-20 

60g

BL296SB-16FS-4A-20

60g

BL296XB-16FS-4A-20

60g

BL296PB-16FS-4A-20

60g

Monitoring 

function

Mass

BL296SB-16F-4A-20
BL296XB-16F-4A-20
BL296PB-16F-4A-20
BL296SB-16FS-4A-20
BL296XB-16FS-4A-20
BL296PB-16FS-4A-20

Consumption 

current

Transmission side I/O side

*

4

8 mA
8 mA

8 mA
8 mA
8 mA

8 mA

80 mA
50 mA

80 mA
50 mA
15 mA

15 mA

Up to 1ms

Ambient temperature use
Ambient humidity use
Temperature/humidity storage 
Atmosphere
Altitude use

*

1

Pollution level

*

2

Noise resistance

0 - +55

10 - 90%RH No condensation
-25 - +75

No corrosive gas
0 - 2000m

2 or less
1200Vp-p (pulse width 1μs)

(Do not preserve or use under an environment pressurized equal to 

or higher than the atmospheric pressure at the altitude of 0m)

Power supply voltage use
Transmission method
Synchronization method
Transmission procedure
Connection mode
Number of connection points
Number of connection points

24V DC +15% to -10% (21.6 to 27.6V DC) with a ripple of 0.5Vp-p or less

DC power supply superimposed total frame/cyclic method
Frame/bit synchronization method
Dedicated protocol
Bus type (Multi-drop method, T-branch method, Tree branch method)
512 max. (IN: 256, OUT: 256)
Up to 128 units

*1 Do not use or store AnyWireASLINK equipment under an environment pressurized higher 

than the atmospheric pressure at an altitude of 0m. Otherwise, a malfunction may occur.

*2 This is an index that shows the occurrence level of conductive substances in the 

environment where the equipment is used.
In the case of pollution level 2, only non-conductive pollution occurs.
However, this is an environment where temporary conductivity can occur by accidental 
condensation.

*3: The time from detection of ON or OFF to sending of a transmission 

signal. This time + 2 transmission cycle times is the transmission 

delay time.

*4: * The value on the input terminal is the value when all points between 

       IN and 0V (NPN) or between 24V and IN (PNP) are shorted.

       When connecting a 3-wire sensor, add the total consumption current 

       of the sensor.

    * The value on the output terminal is the value when all points are ON.  

      Add the total connected load consumption current.

    * The value on the output terminal is the value when all points are ON. 

      Add the total connected load consumption current.

Summary of Contents for BL296 B-16F Series

Page 1: ...ay occur Use a stable 24V DC power supply Use of an unstable power supply may cause problems with the system Although the AnyWireASLINK has a high noise margin keep the transmission line and I O cable...

Page 2: ...ocation where the atmosphere is free of corrosive gas flammable gas and sulfur Location where the unit is removed from high voltage or high current cables Location where the unit is removed from cable...

Page 3: ...VE POWER IN SLAVE General purpose power supply filter Use it if necessary General purpose power supply filter Use it if necessary Insert the ASLINK filter Type ANF 01 regardless of installation method...

Page 4: ...0V PE 24V 0V 24V 0V PE DP DN 24V 0V DP DN 24V 0V 4 wire terminal 4 wire terminal A B Power supply to the entire system Local power supply branching LINE LOAD LINE LOAD AnyWireASLINK master AnyWireASLI...

Page 5: ...ddress writer The port cannot be seen from the surface The state in which the installation dedicated DIN rail adapter is mounted and fixed in the same direction as the DIN rail The state in which the...

Page 6: ...10P 4 3 2 1 A B C Cover Pressure weld using a dedicated tool so that the fittings of the body are in the holes of the cover After pressure welding make sure to check that hooks to are securely engaged...

Page 7: ...damaged Check if the master unit is powered and if necessary please contact our helpdesk 3 If the LINK of the master unit does not flash check if the master unit is powered Other system errors may als...

Page 8: ...to use a 4 wire insulated terminal Otherwise a malfunction may occur In the case of an inductive load mount a surge killer If the power is turned on with the circuit between OUT and 24V shorted passiv...

Page 9: ...rminal Otherwise a malfunction may occur In the case of an inductive load mount a surge killer If the power is turned on with the circuit between OUT and 24V shorted passive elements will be damaged C...

Page 10: ...00Vp p pulse width 1 s Do not preserve or use under an environment pressurized equal to or higher than the atmospheric pressure at the altitude of 0m Power supply voltage use Transmission method Synch...

Page 11: ...11 11 Printed in Japan 2016 2017 UMA 13221C EN Anywire Corporation Headquarters 1 Babazusho Nagaokakyo shi Kyoto 617 8550 JAPAN Contact by mail Contact info_e anywire jp Contact by website http www an...

Reviews: