Software functions
7-24
7.4.8. Reboot
It is possible to reboot the main unit.
7.4.9. Default setting
The device can be temporarily started using the default setting if you cannot remember the IP address.
The procedure is as follows.
Turn off the power.
Turn on the power while holding the SET button. Place your finger so that the LED on the side of the
button is visible at this time.
The LED on the side of the SET button flashes after approximately 20 seconds.
Release your finger from the button.
The IP address is "192.168.0.36" in this state. Access the device from a browser to check or change the IP