1.5.2.2 Peak/Normal Weighing Mode
When the “Set” symbol is displayed, Peak mode is activated. Display shows the maximum
value of load which has been applied to the load cell. When the load is removed, display still
shows the peak load.
When the “Set” symbol isn’t displayed, Peak mode is deactivated. Value shown on display
changes according to the load applied to the load cell.
Press
【
GR/NET
】
can change indicator from Peak mode to Normal Weighing mode, or vice
versa.
1.5.2.3 Remove Peak Mode Value
When Peak mode is on (The “Set” symbol is displayed), remove the load and press
【
TARE
】
.
Peak mode value is removed, and indicator starts another Peak mode operation.
1.5.2.4 Zero Scale
When Peak mode is on (The “Set” symbol is displayed), press
【
GR/NET
】
to switch
indicator to Normal Weighing mode.
Remove the load and when the “Stable” symbol is displayed, press
【
ZERO
】
. Display shows
zero value.
1.5.2.5 Print
When Peak mode is on (The “Set” symbol is displayed), press
【
】
and Peak value is
printed. When the Peak mode is off, press
【
】
and the current load value is printed.
After each printing, the Consecutive Number is increased by 1. The Print format is set
according to F8 Menu (refer to Section 7 for Print Format).
1.5.3 Count Mode Operations
When F5.1 Menu is set to Count mode (F5.1=2), The “Count” symbol is displayed. Indicator
is in the Count mode operations (refer to F5.1 Menu for setting).
Basic operations in Count mode:
1.5.3.1 Gross/Net Mode
Press
【
GR/NET
】
to switch between Gross weight to Net weight. When in Tare mode, Net
weight is equal to Gross weight less Tare weight.
The ”Gross” symbol is displayed when in Gross mode.
The ”Net” symbol is displayed when in Net mode.
1.5.3.2 Units
Press
【
UNITS
】
, switch between the weight of load and the quantity of count items. When
showing the weight of load, follow F2.3 Menu to choose the unit (refer to F2.3 Menu).
When showing the quantity of count items, display shows “nxxxxx”. xxxxx is the quantity of