- 31 -
quantity. Press
to go to the next menu. Display shows “F5.5”.
(
6
)
Press
when display shows “F5.5”. Display shows “CAL” while processing the
average weight setting. When complete, there are 2 possible outcomes :
z
The average weight is too small and display shows “—E5—“. Press
to
return to F5.5 Menu and display shows “F5.5”. There are two options :
Combine a few small items as one sample. Place the same sampling
quantity as specified in F5.4 Menu. Press
to perform the average
weight calculation.
Press
to cancel average weight setting and return to F5 Menu.
Display shows “F5”.
z
The average weight is normal and display shows the quantity of the count item
“nxxxxx”. Press
,
to edit count item quantity and weight. Press
to
return to F5.2 Menu and display shows “F5.2”
(
7
)
There are 2 options when display shows “F5.2”.
z
Repeat (3) to (6) if another average weight setting is required.
z
Press to return to F5 Menu if no more average weight setting is required.
Display shows “F5”.
(
8
)
Turn off the J1 switch to exit from the configuration mode and enter into
weighing mode.
6. Relay Output Setup
There are two signal outputs, one lower and one upper, in the Relay function. When the
weight value (see Note 2) is smaller than the setting in F6.2, Relay 1 is on. When it is
greater than the setting in F6.2, Relay 1 is off. When the weight value is smaller than the
setting in F6.3, Relay 2 is off. When it is greater than the setting in F6.3, Relay 2 is on.
See Fig. 6-2.
Setup procedure :
(
1
)
Set indicator to Configuration mode (display shows “F1”).
(
2
)
Press
until display shows “F6” (see Fig. 6-1). Press
to go to the Relay
Output Menu. Display shows “F6.1”
(
3
)
When displays shows “F6.1”, press
to go to the F6.2 Menu and display shows
“F6.2”.
(
4
)
When display shows “F6.2”, press
and display shows the value of Relay 1
setting. Edit Relay value according to editing procedures in Fig. 4-2. When
complete, press
to store the value and return to F6.3 Menu. Display shows
“F6.3”.
(
5
)
When display shows “F6.3”, press
and display shows the value of Relay 2
setting. Edit Relay value according to Fig. 4-2. When complete, press
to store
the value and return to F6.1 Menu. Display shows “F6.1”.