- 22 -
1 (7EVEN)
(
Bits
)
2 (7ODD)
0
(
con
)
F4.3
(
Mode
)
1
(
comm
)
√
Selects the mode of data transmission. 0(con) is
for continuous transmission and 1(comm) is for
transmission upon receiving commands. It must be
set to 1 to use print function. Refer to Section 8.
F4.4
(
Test
)
—
Press
to perform serial communication tests
between two indicators. Refer to Section 8.3
3.2.5 F5(Mode) Menu