![Anybus CompactCom 30 Network Manual Download Page 29](http://html1.mh-extra.com/html/anybus/compactcom-30/compactcom-30_network-manual_2948755029.webp)
Host Application Objects
27 (36)
Extended
#
Name
Access
Data Type
Default
Value
Comment
7
Manufacturer
Hardware Version
Get
Array of
CHAR (Max.
24 bytes)
Object entry
1009h not
implemented
Specifies the value of object entry 1009h (Man-
ufacturer Hardware Version)
8
Manufacturer
Software Version
Get
Array of
CHAR (Max.
24 bytes)
x.yy
Replaces object entry 100Ah (Manufacturer
Software Version)
9 - 13
-
-
-
-
(reserved)
14
Default PDO map
configuration
Get
UINT8
00h
00h:
Standard default PDO mapping
(minimalistic mapping)
01h:
Use all available ADIs for de-
fault mapping (no consistency
checking of the mapping is
done). This must be maintained
by the application by ADI map-
ping order and ADI data typed
mapped.
02h - FFh
(reserved)
Anybus
®
CompactCom
™
30 Network Guide
HMSI-168-78 EN 4.1