Anviz Global Inc 

 

Input Start Date and Ending Date 

 

 

Select 

Link Time

 

 

Normal off duty the office closes the door. So select link time as 0 

 

 

Input 

time range

 for working time and select week period. 

Because the working time range is: 9:00—18:00 from Monday ---Friday.   
So we just need use 

1st Time Zone Start—1st Time Zone End

 that’s enough.   

And the time range of the 

1st Time Zone

 we had best more loose time range (Some body will 

early in office and later out office)

 

 

Upload the Time Zone to controller 

Summary of Contents for DAC844

Page 1: ...AIM DAC System 1 Anviz Global Inc DAC844 User Manual ...

Page 2: ... with the maximum number of functions including future options Therefore not all functions described in this manual may be available in the specific system and or product configuration you purchased 5 Incorrect operation or installation or failure of the user to effectively maintain the system relieves the manufacturer and seller from all or any responsibility for consequent non compliance damage ...

Page 3: ...itch and Door Contact Wiring 10 2 3 3 Lock connection 11 2 3 4 RS485 Wiring 11 2 3 4 LED 12 3 DAC system Overview 13 3 1 Starting the Software 13 3 2 Starting the Software 14 3 3 Device Management 15 3 3 1 Controller Operation 15 3 3 2 Door Operation 22 3 3 3 Time Zone 25 3 3 4 Privilege 28 3 3 5 First Card 33 3 3 6 Multi Card 37 3 3 7 Crontab 40 3 3 8 Access Records 41 3 4 User management 42 3 5 ...

Page 4: ...records huge storage capacity meet the medium scale enterprise access control requires Support 4 standard Weigand26 readers input Both with TCP IP and RS485 communication mode easily upgrade the access control without rewiring The DAC844 combine with Anviz intelligent management Distributed Access Controller system AIM DAC system The DAC system is user friendly intuitive and rich in functionality ...

Page 5: ... previous exit Door Interlock Door Interlock sometimes referred to as Mantrap prevents two or more related doors from opening at the same time It may be useful for the entry holes of Clean Rooms or in other facilities with two exit doors It should only be possible to open one door at a time with a valid user code The Door Interlock must have door contact equipment First Card function The First Car...

Page 6: ...Duress Open Door Record and Door Status Need door contact equipment 1 2 Product parameters Parameter Describe Working Power 12V 4A Max Min Working Current Standby 86mA Max 560mA Input 4 Switching Signals 4 door contacts Relay 4 relays 12V 5A NO NC COM LED prompt 22 LEDs Communication TCP IP RS485 115200bps Working Temperature 10 50 Working Humidity 0 80 Size 128 128 15mm H W D Weight ...

Page 7: ...AIM DAC System 7 Anviz Global Inc 2 Product Operation 2 1 Product Communication 2 1 1 Net Work Communication wiring TCP IP Communication Mode ...

Page 8: ...AIM DAC System 8 Anviz Global Inc 2 1 2 RS485 Communication RS485 Communication mode ...

Page 9: ... Describe NO Describe 1 Power Input 7 4 Switching Signal Input 2 Min USB port Upgrade firmware 8 4 Door Contact Input 3 TCP IP port 9 4 Relay Output NO NC COM 4 RS485 port A B GND 10 4 Readers Input 5 I2C Expand Port 11 Restart Button 6 Fire Alarm input Earth ...

Page 10: ... below steps wiring with DAC844 1 Please make sure the DAC844 connect with Earth 2 Connect with Reader Switch and Door Contact equipment 3 Connect with Lock 4 RS485 communication 5 LED prompts 2 3 1 DAC844 Earth Wiring Earth 2 3 2 Reader Switch and Door Contact Wiring ...

Page 11: ...AIM DAC System 11 Anviz Global Inc Remark Exit Button means Switch Door Sensor means Door Contact Reader Switch and Door Contact 2 3 3 Lock connection Lock and Relay 2 3 4 RS485 Wiring RS485 Wiring ...

Page 12: ... 4 LED LEDS No Describe Y Yellow G Green Switch Signal prompt LEDs Y Door Contact prompt LEDs Y Relays prompt LEDs G Reader Wiegand 26 input prompt LEDs G RS485 Communication prompt LEDs Left Y Right G Fire Alarm Input G Power G WatchDog G ...

Page 13: ... This section explains how to start the software and log in to the main window Staring DAC System Click the DAC icon on the desktop or select the program from the DAC folder in the Start menu The DAC Software login dialog appears DAC Software Dialog box 1 Enter a Use Name and type a Password 2 Click Confirm The main DAC window opens Note By default the User Name is admin and Password is 1 Note The...

Page 14: ... from its main window Figure 3 2 AIM DAC System Main windows The AIM DAC System Main window has three Parts Section Description Controls the software general operation and device setup Controls register User information in the System Monitoring all the access alarms and error events Click back to AIM DAC System Main windows ...

Page 15: ...controllers will display in the Controller list 3 3 1 Controller Operation Controller option has two parts Part One Edit Add and edit the DAC844 device information into the software Controller S N After added the controller in the software the administrator could select controller via the controller ID Search Click Search option into Quick Add Device interface ...

Page 16: ...ce in the software Add To manual to add a DAC844 device The DAC844 support two connection mode TCP IP and RS485 connection mode TCP IP mode Please enter the Controller No The Controller NO is the unique ID of the DAC844 You can find it in the DAC844 Package or on the DAC844 product lable It is a 6 digit number Such as 44893 Select LAN in Connection Mode and input IP address which you need Detail I...

Page 17: ...igit number Such as 44893 Select COM in Connection Mode and Select Com Port number in the drop down list Detail Info Input DAC844 devices describe information Save To save the device setting Cancel To cancel the device setting Delete Please select DAC844 device in the Contorller list and click Delete to delete device Modify Click Modify to input DAC844 devices describe information and change the d...

Page 18: ...ne means the relay in standby When someone accessed the device the relay will open NO means the relay always open NC means the relay always close Timing Setting the time to the device The device will synchronize the time with PC system Synchronization Select this option will help administrator quick setting all the relay in the device The administrator just needs setting the first relay status the...

Page 19: ...d Reader D two readers make up an Anti Passback application A B C D Four Readers make up two areas Anti Passback application Please click Setup upload all the settings in the DAC844 device Interlock Enable door Interlock to prevent two doors from opening at the same time It should only be possible to open one door at a time with a valid user code In the drop down box there are three options A B Re...

Page 20: ...functions Enable PIN Pad Enable PIN Pad function the DAC844 device will support the KEY pad reader and number input from the KEY pad And the Duress Password function can be used Enable password After enable this function the DAC844 could be accessed by Super Password Card Password Enable this function The user could input Card number and Password to access the DAC844 without carry the card Or the ...

Page 21: ...n the DAC844 device Communication Check and modify the DAC844 device network parameter Search Click Search the software will find out the selected DAC844 s network parameter You can modify all the network parameter except MAC Addr Please click Setup save and upload all the settings in the DAC844 device Clear To clear the settings in the DAC844 device Please select the settings which you want to cl...

Page 22: ...ministrator to remark the door There are two parts in Door Edit interface include All the Door and Controller Door All the Door Listed out all of doors in each controller Controller Door list out selected DAC844 controller s door The administrator could edit door information via select controller Controller ID Input controller ID and click Select all of doors will list in controller door column ...

Page 23: ...ee columns in the Door Group interface Door Groups List Added Group List and Unorganized Group List Door Group List List out created door groups Added Group List List out the door which have added in the group Unorganized Group List List out the door which do not have added in the group Please click Add to create a group Input group name and information Note Because different DAC device support di...

Page 24: ...e selected door to Added Group List or click put the door out from Added Group List By now doors in the Unorganized Group List reduced Delete Delete the door group Select the door group in the Door Group List click Delete to delete Modify Modify the door group information Select the door group in the Door Group List click Modify to edit door group information ...

Page 25: ...t the time zone 0 and 1 are fixed time zones Time Zone 0 Normal Close means all users with time zone 0 that can not pass access the door Time Zone 1 Pass any time means all users with time zone 1 that can pass access the door at any time Time Zone No the software can set 255 time zones The time zone 0 and 1 is fixed Time Zone Name Input a name to describe the time zone Start Ending Date Date range...

Page 26: ... make up a time zone After setup a time zone please click Add The time zone will add into AIM DAC system Then need select a controller the controller which need with this time zone in Controller List and click Upload to upload the time zone to selected controller The system will pop up a window to prompt succeed or failed For Example Access control for normal working time Start working time is 9 0...

Page 27: ... 5 Input time range for working time and select week period Because the working time range is 9 00 18 00 from Monday Friday So we just need use 1st Time Zone Start 1st Time Zone End that s enough And the time range of the 1st Time Zone we had best more loose time range Some body will early in office and later out office 6 Upload the Time Zone to controller ...

Page 28: ...roller Click Upload to upload time zone to DAC844 device 3 3 4 Privilege Privilege option It is according to the rules of time zone authorized the user privilege to pass the door or not allowed to pass the door Note Please refer to the section User Management first Before setting Privilege ...

Page 29: ...de of the Door Door Group area list out all of doors and door groups Click put all of doors or door groups to right side Click put select single door or door group to right side The selected doors and door groups will list in right side of the Door Door Group area ...

Page 30: ...in the AIM DAC system Click put all users to right side Click put single user to right side The selected users will list in right side of the User area Click to put all users back to left side Click to put single user back to left side Add Time Zone area Time Zone No Please select time zone in the drop down box Name Display Time Zone name Start Date End Date This date range is the privilege expiry...

Page 31: ...up select the user and set the time zone the next is authorizing Click button the user authorized pass the door Click button the user cannot pass the door Note After authorized the user pass the door The Ban Pass the door function uses to cancel user pass door privilege ...

Page 32: ...vilege has made up and store in the system database Now we need upload these access control privilege to the corresponding DAC844 devices In the Upload interface please select corresponding DAC844 controller in the Controller list Click to upload Access control privileges to the Controller ...

Page 33: ...ard All of the administrator cards could with First Card function The First Card controls the status of a single door So before setting First Card function needs select a controller in the Controller List and select a door in Edit column First Card Time It is time point The first card must be verified at this time point the door will change the status Note Must enable First Card function in the sy...

Page 34: ...AIM DAC system Click put all users to right side Click put single user to right side The selected users will list in right side of the User area Click to put all users back to left side Click to put single user back to left side Note The time before this time point to verify the first card The door cannot change the status And the door must verify the first card to change status when the time over...

Page 35: ... DAC system Modify After modify the first card informations and click Modify to save in the system The next step is to upload the first card information to controller In the Upload interface click first card information You could check the firs card members in the right list Click Upload to upload first card information to controller Note You can back to Edit interface to Modify or Delete first ca...

Page 36: ...AIM DAC System 36 Anviz Global Inc ...

Page 37: ...s at same time The Multi Card function also controls a single door So administrator needs select a controller in the Controller List and select a door in Edit column After selected the door click Add and Continue Operation will pop up below window Note Must enable Multi Card function in the system Please refer to 3 3 1 Controller Operation First Card Multi Card ...

Page 38: ...r This is total number of cards need verified The maximum number is 200 Multi Card Group There are 8 groups The Group can make multi card function more agile Click or to assign user to different groups For example There are 4 groups with different users ...

Page 39: ...ser in these groups Click Add will make up all multi card informations store in the system database and click Upload to upload all multi card informations to controller Click Delete to delete Multi Card setting in the AIM DAC system database After modified the Multi Card setting in the AIM DAC system please click Modify to save the settings Note The Multi Card function must work with Multi Card Gr...

Page 40: ... Door change status when at execution time Door Select a door will have crontab function The DAC844 normal with 4 doors Select a conntroller in the conntroller list and Click Add will make up crontab informations store in the system database and click Upload to upload crontab informations to controller Before upload crontab informations to controller The administrator could click Delete to delete ...

Page 41: ... include two parts Extract recrods and Browse The Extract records interface could download the access records from controller Select All Download all records from all of controllers The Browse interface could select records according the condition setting in the software ...

Page 42: ...o in the User list So this serial number cannot be repeated That s unique number for user Name Input the User name Statue the user account s statue There are two statuses Normal and Cancel The Normal means the register user been active in the system Cancel means the register user do not been active in the system Password The user s password for verify the access controller Then click Add button Th...

Page 43: ...oll ID in the drop down list and click Select to active Qucik Add function Then administrator could swipe the card on any readers which connect with the DAC844 device Then in the below list will display all the card numbers When you finsih swipe cards Please click Stop first and click Add button all of cards will add in the AIN DAC software ...

Page 44: ...ot input any number Step 2 Connect the T5 reader with AIM DAC system via the USB cable Step 3 Click Collect will active the T5 reader to register fingerprint Please hold press the fingerprint on the T5 reader When you see the clear finger image in the system Please click Fingerprint 1 Registration to register one fingerprint Then you need click Collect and Fingerprint 2 Registration to continue re...

Page 45: ... T5 reader via the TCP IP communication Step5 Enter Quick Add interface select the controller ID and active Quick Add function and press the fingerprint on the T5 reader Then the T5 will send out a number to AIM DAC System And we could use this number to the user who we register in the Step 1 Then the user with fingerprint registered in AIM DAC System Note After register fingerprint you could veri...

Page 46: ...fer to the section 3 3 4 Privilege to authorized user 3 5 Real Time Monitoring Enable the Real Time Monitoring function the AIM DAC System could display any operation in the system monitoring windows Click Monitoring button will enable the Real Time Monitoring function ...

Page 47: ...ler need with door contact equipment The administrator could select the icon of the door and right click the mouse The doo could opened by remote Stop Click Stop to stop monitoring the controller Map AIM DAC system support import image The administrator could import the building floor maps into the system So could put the door icon on the maps to monitoring The image support BMP and JPGE ...

Page 48: ...ring windows we can also support multiple records Such as Exit button open the door Swipe the card to open the door And the abnormity warning also display in the software The abnormity warning will display in the right side of the Real Time Monitoring windows ...

Page 49: ...lization button in the access controller The user could hold press the initialization button for 4 5 sec and the reader prompt LEDs will flash 8 9 times After initialization the controller all the user information will not be clearly Only the IP address back to default IP address 192 168 0 150 ...

Page 50: ... Mini USB port When you need upgrade the firmware please hold press initialization button and power on the DAC844 The DAC844 device wills only bright Power LED Running the below icon Will display the windows as below Click icon to find the firmware files And click Update to upload the firmware to DAC844 device ...

Reviews: