connection mode.
Part Two:
Setting: It is general operation and device setup. Include “Status”, “Advanced”,
“Password”, “Communication” and “Clear” functions.
At the left side of the “Setting” interface display the selected DAC844 device’s information;
include “Controller No.”, “Connection Mode” and Device status.
“
Status
”:
controls each relay and relay status on the DAC844. (The DAC844 have 4 relays
output.)
“
Door Open Delay
”:
controls the relay working delay time. (3000 means 3000ms. The
minimum delay time is 100ms. ms=
millisecond)
“
Door Status
”:
There are three door statuses. Online, NO and NC
“
Online
”
means the relay in standby. When someone accessed the device the relay will open.
“
NO
”
means the relay always open.
“
NC
”
means the relay always close.
“
Timing
”:
Setting the time to the device. The device will synchronize the time with PC system.
“
Synchronization
”:
Select this option will help administrator quick setting all the relay in the
device. The administrator just needs setting the first relay status, the others relays will have the
some status as the first one.
After setting all the status of the delay, please click “
Setup
” upload all the settings in the
DAC844 device.
“
Advanced
”: Controls the advanced functions in the DAC844 device. Include “First Card, Multi
Card”, “Anti-Passback”, “Interlock” and “Forced Password” functions.
“
First Card, Multi Card
”: Enable the First Card and Multi Card function. The Multi Card need