background image

13

P/N 1010454 Rev. F 12/16

REPLACEMENT PARTS (continued)

0010159  Filter Assy., Water Tank  1

2  7000652 Relay 

1

3  7000320  Spatula Kit  

 

 

(Incl. #20, 25, 36, 38, 74) 

 

 

(MS-150 only)

7000137  Pump/Tube Assy.,  

 

 

24VAC  

5  0503429  Support, Generator  

  

Upper 

6  7000237  Top Cover Assy.  

 

 

(Incl. #41 & 42) 

0011314  Steam Vent Assy. 

1

0021131  Floor/Chassis Weld. 

1

9  0012298  Access Cover Weld.  

1

10  7000246  Generator, 230V 

1

 

7000245  Generator, 208V 

1

 

7000300  Generator, 120V 

1

11  0300129  Stud, Cover Hold Down  1
12  040P138*  Locknut, 1/2" 

1

13  040K251  Strain Relief (Incl. #12)  1
14  05P2199* Spacer 

2

15  0503431  Diffuser, Steam 

1

16  7000849  Silicon Tube Kit,  

 

 

Water Pump 

17  0503433  Cover, Generator 

1

18  0503434  Cover, End Housing 

1

19  0503435  Retainer, Thermocouple  1
20  0503988  Spatula  

 

 

(Mfg. Nos. 9100420,  

 

 

 

9100425, 9100426, 

 

 

9100428 only) 

 

21  0021571  Spatula  

 

 

(Mfg. No. 9100423 only) 

22  0021314  Liner, Cavity  

 

 

(MS-150 only) 

23  0503472  Bracket, Hi-Limit  

  

Support 

24  0700452  Power Cord,  

 

 

NEMA 6-20P 

 

 

 

(Mfg. No. 9100420,  

 

 

 

9100426, 9100450,  

 

 

& 9100456)

 

0700453  Power Cord, CEE 7/7 

 

 

(Mfg. No. 9100419, 

 

 

9100428, & 9100458)

 

0700463  Power Cord,  

 

 

NEMA 5-15P 

 

 

 

(Mfg. No. 9100423,  

 

 

 

9100425, & 9100452)

 

0700437  Power Cord IEC-309  

 

 

Pin and Sleeve (Mfg. No. 

  

9100459)

25  0800359  Trivet, Spatula  

 

 

(MS-150 only) 

26  100P967  Label, Marking 

1

27  1001036  Label, Control Panel  

1

28  2000203  Tube, Restrictor, 1/4” 

1

29  0011370  2" Leg Kit (Incl. #35) 

4

29a 210K134  4" Leg Kit (not shown)  1
29b  210K123  4" Leg Kit (optional)  

 

 

(not shown) 

30  0011413  Liner Assy.  

 

 

(MS-155 only) 

31  2040106  Adapter, Tube/Hose 

1

32  2040145  Elbow, Female,  

 

 

1/8" x 1/4" 

33  2040146  Tee, Female,  

 

 

1/8" x 1/4" 

34  7000693  Water Fitting Kit 

1

 

 

(Incl. #28, 31, 32, & 33)

35  210K108  Foot, Rubber (4 Pack)  1 

36  2100119  Handle, Spatula  

 

 

(MS-150 only) 

37  4050180  Heat Sink 

1

38  2100118  Guard, Handle  

 

 

(MS-150 only) 

39  0503536  Drip Pan  

1

40  0021237  Liner Weldment  

 

 

(MS-155 only) 

41  2100249  Guard, Knob 

42 2100273  Knob 

1

43  211P101  Clamp, Hose, 3/8" 

1

44  211P195*  Clamp, Hose 

1

45  306P107*  Acorn Nut, #6-32  

 

 

(MS-155 only) 

46  7000446  Generator Tube,  

  

3-5/8" 

47  306P137*  Stud, PEM, #6-32 x 3/8"  2 

 

 

(MS-155 only) 

48  300P102*  Nut, Speed, “U”,  

  

#8-32 

49  304P105*  Nut, Hex, KEPS,  

 

 

#4-40, Zinc 

50  306P101*  Nut, Hex, #6-32 

2

51  306P105*  Screw, Machine,  

 

 

#6-32 x 1/2"  

52  306P123*  Screw, Machine,  

 

 

#6-32 x 7/8" 

53  306P130*  Nut, Hex, KEPS, #6-32  2
54  306P134*  Screw, Machine,  

 

 

#6-32 x 3/8" 

55  308P103*  Screw, Machine,  

 

 

#8-32 x 1/4" 

56  325P132*  Screw, Machine,  

 

 

1/4-20 x 1/2" 

 

 

 

(MS-155 only) 

57  308P105*  Screw, Machine,  

 

 

#8-32 x 1/2" 

 

58  308P120*  Screw, Machine,  

 

 

#8-32 x 5/8" (sltrshd) 

59  308P124*  Screw, Machine,  

 

 

#8-32 x 1/2"  

 

 

(one way) 

60  308P143*  Nut, Hex, KEPS, #8-32  2
61  310P136*  Screw, Machine,  

 

 

#10-32 x 1-1/4"  

  

(splanhd) 

62  310P149*  Screw, Machine,  

 

 

#10-32 x 7/8" 

63  310P149*  Screw, Machine,  

 

 

#10-32 x 7/8"  

 

 

(MS-150 only) 

64  325P170*  Nut, Wing, 1/4-20 

1

65  7000542  Rocker Switch,  

 

 

Power On/Off 250V 

 

7000543  Rocker Switch,  

 

 

Power On/Off 120V 

 

66  4010166  Switch, Momentary  

  

(Green) 

 

 

4010190  Switch, Momentary  

  

(White) 

67  7000319  Transformer,  

  

115-230/24V 

68  7000135  Thermostat, Hi-Limit 

1

69  4050214  Thermocouple, Type-K  1
70  406P107  Cable Tie 

3

71  7000136  Terminal Block, 3-Pole  1
72  7000317  Control Board,  

 

 

Replacement Kit 

 

 

7001420  Control Board 

1

 

 

Replacement Kit 

 

 

(Mfg. No. 9100442 only)

73  05P2991  Spacer (MS-155 only)  2
74  338P102*  Bolt, Handle Mounting 1 

 

 

(MS-150 only) 

75  0011471  Drawer Assy.  

 

 

(Incl. #, 45, 47, 56, 73,  

 

 

76, 77, 78, 79) 

 

 

 

(MS-155 only)

76  0021283  Drawer Weldment  

 

 

(MS-155 only) 

77  210K195  Bearing, Roller, SS 

 

 

(Incl. #73) 

 

 

(MS-155 only)

78  2100257  Handle (MS-155 only)  1
79  2100264  Guard, Handle  

 

 

(MS-155 only) 

* Only available in quantities of 10.

 Item Part No.  Description 

Qty.

 Item Part No.  Description 

Qty.

 Item Part No.  Description 

Qty.

Summary of Contents for MS-150

Page 1: ...P N 1010454 Rev F 12 16 MS 150 155 owner s manual miracle steamers Manufacturing Numbers 9100419 9100420 9100423 9100425 9100426 9100428 9100442 9100450 9100452 9100456 9100458 9100459 www antunes com ...

Page 2: ...rials when filing a claim Freight damage claims are the respon sibility of the purchaser and are not covered under warranty The warranty does not extend to Damages caused in shipment or dam age as result of improper use Installation of electrical service Normal maintenance as outlined in this manual Malfunction resulting from improper maintenance Damage caused by abuse or careless handling Damage ...

Page 3: ...ctrician Do not use an extension cord with this appliance Electrical ground is required on this appliance Check with a qualified electrician if you are unsure if the appliance is properly grounded If a chemical cleaner is used be sure it is safe to use on cast aluminum Observe all precautions and warnings on product label Inspection testing and repair of elec trical equipment should only be per fo...

Page 4: ...300 15 9 50 60 NEMA 6 20P 20 Amp 250 Volt MS 155 9100450 208 3300 15 9 50 60 NEMA 6 20P 20 Amp 250 Volt MS 155 9100452 120 1800 15 0 50 60 NEMA 5 15P 15 Amp 120 Volt MS 155 9100456 230 3300 14 4 50 60 NEMA 6 20P 20 Amp 250 Volt MS 155 9100458 230 3300 14 4 50 60 CEE 7 7 16 Amp 250 Volt MS 155 9100459 Saudi Arabia 230 3300 14 4 50 60 IEC 309 16 Amp 250 VAC Pin Sleeve Assembly Only Model Mfg No Agen...

Page 5: ...2 Washing Parts MS 155 Only Spatula Wire Trivet Drip Pan Drawer Drawer Liner with Rollers Drip Pan Spatula Liner Figure 1 Washing Parts MS 150 Only Figure 3 Assembling Handle MS 150 Only Bolt Handle Spatula Handle Guard Wire Trivet ELECTRICAL Plug the power cord into the appropriate power outlet Refer to the specification plate for the proper voltage 1 Place the unit on a sturdy level table or oth...

Page 6: ...and press or to change the Total Cycle Time in seconds 5 To change the SHO factory settings make sure the control is in PROGRAM mode then press and hold both and simultaneously for 1 2 seconds and release SHO will be displayed 6 Press and release and then press or to change the SHO in seconds 7 Press and release again and press or to change the SHO in minutes 8 Press and release again and H2O will...

Page 7: ...the SHO and H2O settings be adjusted to the recommended settings shown in the Programming section of this manual DAILY MAINTENANCE 1 Turn the power off unplug the power cord and allow the unit to cool down before proceeding 2 MS 150 Remove the Spatula Spatula Liner Drip Pan Top Cover and Steam Vent Figure 7 MS 155 Remove the Drawer Drawer Liner with Rollers Drip Pan Top Cover and Steam Vent Figure...

Page 8: ...le 4 Clean the Filter by running it under tap water Replace the Filter if the screen is torn or damaged 5 Reinstall the Filter Stem into the bot tom hole of the tank Figure 10 6 Fill the Water Tank close the Tank Door and test the unit NOTE Do NOT overfill the unit s water tank Only fill the tank to 90 full 7 Using a sponge or a dry towel remove the delimer solution from the Generator surface then...

Page 9: ... State Relay is inoperable Thermocouple is inoperable Control Board is inoperable Steam Generator is inoperable Loose burnt or broken wires in circuit The unit s main electrical panel circuit breaker trips Damaged receptacle plug or cord a loose connec tion or an internal component failure Turn the unit off allow it to cool down and then restart Contact your maintenance person or Antunes Technical...

Page 10: ...aintenance section of this manual Generator surface is bare Generator surface must have a thin calcium mineral coating for proper steaming Refer to the Maintenance section of this manual Generator Steam Ports are restricted Clean the Steam Ports as described in the Maintenance section of this manual Generator Cover is warped or loose Verify that the Generator Cover Wing Nut is tight If noticeable ...

Page 11: ... P N 1010454 Rev F 12 16 WIRING DIAGRAM NOTE For 208 240 VAC units the two primary coils are wired in series with one another For 120 VAC units the two primary coils are wired in parallel with one another ...

Page 12: ...12 P N 1010454 Rev F 12 16 REPLACEMENT PARTS RE AD Y 64 17 15 18 20 74 36 22 66 75 73 40 30 77 77 73 76 56 79 78 47 45 65 6 7 8 10 12 13 24 62 29 35 70 57 54 54 54 42 41 39 38 25 5 3 74 36 38 25 21 11 ...

Page 13: ...50 only 37 4050180 Heat Sink 1 38 2100118 Guard Handle 1 MS 150 only 39 0503536 Drip Pan 1 40 0021237 Liner Weldment 1 MS 155 only 41 2100249 Guard Knob 1 42 2100273 Knob 1 43 211P101 Clamp Hose 3 8 1 44 211P195 Clamp Hose 1 45 306P107 Acorn Nut 6 32 2 MS 155 only 46 7000446 Generator Tube 2 3 5 8 47 306P137 Stud PEM 6 32 x 3 8 2 MS 155 only 48 300P102 Nut Speed U 2 8 32 49 304P105 Nut Hex KEPS 2 ...

Page 14: ...14 P N 1010454 Rev F 12 16 READY 43 31 32 33 23 55 28 46 72 69 49 48 67 49 71 51 57 55 37 68 19 55 26 59 60 27 43 1 55 4 49 43 46 2 16 16 16 34 9 REPLACEMENT PARTS continued ...

Page 15: ...50 only 37 4050180 Heat Sink 1 38 2100118 Guard Handle 1 MS 150 only 39 0503536 Drip Pan 1 40 0021237 Liner Weldment 1 MS 155 only 41 2100249 Guard Knob 1 42 2100273 Knob 1 43 211P101 Clamp Hose 3 8 1 44 211P195 Clamp Hose 1 45 306P107 Acorn Nut 6 32 2 MS 155 only 46 7000446 Generator Tube 2 3 5 8 47 306P137 Stud PEM 6 32 x 3 8 2 MS 155 only 48 300P102 Nut Speed U 2 8 32 49 304P105 Nut Hex KEPS 2 ...

Page 16: ...ty does not cover water contamination problems such as foreign material in water lines or inside solenoid valves It does not cover water pressure problems or failures resulting from improper incorrect voltage supply This warranty does not cover Travel Time Mileage in excess of 2 hours 100 miles 160 km round trip from the nearest authorized service agency 2 Roundup reserves the right to make change...