4.5 Cut-Off Solenoid Connection
7KHLQVWDOODWLRQRIDFXWRႇVROHQRLGLVDUHFRPPHQGHG
RSWLRQIRUDOO9ROWHOHFWULFOLIWJDWHV,QVWDOOLQJDFXWRႇ
solenoid will help to prevent accidental or unauthorized
use of the liftgate.
7KHRSWLRQDO$&XW2ႇ6ROHQRLG.LWFDQEHXVHG
in any truck, but is essential for tilt cab applications, as it
requires only a lightweight wire running to the cab, not a
ODUJHFDEOHDVUHTXLUHGE\WKHFXWRႇVZLWFK
Follow the directions on the installation instruction sheet
that comes with the kit.
Cut-Off Solenoid Installed Between Battery and Fuse Assembly.
(2) Short cable, part of solenoid kit. (1) Long length of power cable
leading to power unit.
+
–
Ground
A-1018
Long
Power
Cable
Short
Power
Cable
Short
Power
Cable
Fuse
Vehicle
Battery
Ground
Cut-Off
Solenoid
Fuse Box
On/Off
Toggle Switch
Liftgate
Solenoid
Wiring Diagram with Cut-Off Solenoid.
4.6 Cut-Off Switch Connection
7KHLQVWDOODWLRQRIDFXWRႇVZLWFKLVDOVRDUHFRPPHQGHG
RSWLRQIRUDOO9ROWHOHFWULFOLIWJDWHV,QVWDOOLQJDFXWRႇ
switch will help to prevent accidental or unauthorized use
of the liftgate.
Follow the installation directions on the installation
instruction sheet that comes with the kit.
Cut-Off Switch Mounted in Cab of Truck.
A-1019
+
–
Long
Power
Cable
Fuse
Ground
Vehicle
Battery
Cab
Mounted
Cut-Off
Switch
Short
Power
Cable
Short
Power
Cable
Liftgate
Solenoid
Wiring Diagram With Cab Cut-Off Switch.