Antaira Technologies - Industrial Ethernet Switches
LNX-0500-M12-67 Series User Manual V1.0
7
1.
Insert the positive and negative power wires into the power connector on the industrial
Ethernet switch with pin4, pin1 (V1+, V1-) for power 1, and pin3, pin2 (V2+, V2-) for power 2.
2.
Tighten the screw nut to prevent the connector from loosening.
Caution:
The power input specification is complied with the requirements of
SELV (Safety Extra Low Voltage), and the power supply should be complied
with UL 61010-1 & UL 61010-2-201.