Antaira Technologies - Industrial Ethernet Switches
LMP-0800G-24 Series User Manual V1.0
7
2.6 Ethernet Ports
RJ-45 Ports
RJ-45 Ports (Auto MDI/MDIX)
: The RJ-45 ports are auto-sensing for 10Base-T, 100Base-TX, or
1000Base-T connections. Auto MDI means that the switch can connect to another switch or
workstation without changing the straight-through or crossover cabling. See the figures below for
straight-through and crossover cabling schematics.
RJ-45 Pin Assignments
Pin Number
Assignment
1
Rx+
2
Rx-
3
Tx+
6
Tx-
All ports on this industrial Ethernet switch support automatic MDI operations. Users can use
straight-through cables (see figure below) for all network connections to PCs, servers, and other
switches or hubs. With straight-through cabling, pins 1, 2, 3, and 6 are at one end of the cable and
are connected straight through to pins 1, 2, 3 and 6 at the other end of the cable. The table below
(
Table 2.3
) shows the 10BASE-T/100BASE-TX/1000BASE-T MDI port pin outs.
Note:
The
“+” and “-” signs represent the polarity of the wires that make up each wire pair.
Pin MDI-X
Signal Name
MDI Signal Name
1
Receive Data plus (RD+)
Transmit Data plus (TD+)
2
Receive Data minus (RD-)
Transmit Data minus (TD-)
3
Transmit Data plus (TD+)
Receive Data plus (RD+)
6
Transmit Data minus (TD-)
Receive Data minus (RD-)
Table 2.3 - RJ45 Pin Assignments
Table 2.4 - Ethernet Signal Pin